beautypg.com

Datalogic Scanning GRYPHONTM MX30 User Manual

Page 183

background image

HOST CONFIGURATION STRINGS

A

DATA FORMAT (continued)

NOT FOR PEN EMULATION INTERFACES

DESCRIPTION STRING
Code Length Tx

not transmitted

EE0

transmitted in variable-digit format

EE1

transmitted in fixed 4-digit format

EE2

Field Adjustment

disable

EF0

right

addition

EFa0d

left

addition

EFa1d

right

deletion

EFa2d

left deletion

EFa3d

Field Adjustment Character

EGe

Character Replacement

disable character replacement

EO0

first

character

replacement

EO1afg

second

character

replacement

EO2afg

third character replacement

EO3afg

Address Stamping

disable reader address stamping

RU0

enable reader address stamping

RU1

disable reader address delimiter

RV0

Address Delimiter

enable reader address delimiter and select
character

RV1h


a

= ASCII character.

d

= a number from the Hex/Numeric Table

e, f, g, h

= HEX values representing an ASCII character


a

= ASCII character of the DATALOGIC STANDARD Code Identifier from the table on page 59.

d

= a number in the range 01-32 from the Hex/Numeric Table

e

= Hex value from 00 to FE

f

= Hex value of the character to be replaced from 00 to FE

g

= Hex value of the new character to insert from 00 to FE

FF = replace with no new character (remove character)

h

= a HEX value in the range from 00 - FE representing the ASCII character.

POWER SAVE

DESCRIPTION STRING
Scan Rate

67 scans per sec.

BT0

135 scans per sec.

BT1

270 scans per sec.

BT2

Sleep State/USB Suspend

disable

BQ0

enable

BQ1

Enter Sleep Timeout (100 ms)

BR00-BR99

Standby enable

BM0

disable

BM1

173