beautypg.com

Reading diagrams, 6 reading diagrams – Datalogic Scanning GRYPHONTM MX30 User Manual

Page 174

background image

GRYPHON™ Dx30/Mx30

6

OM-GRYPHON™/C-GRYPHON™ CHARGE STATUS

Red LED

Green LED

Meaning

ON ON

Charging

OFF

ON

End of charge

OFF

OFF

No battery inserted

Flashing

OFF

Discharging (see par. 2.8.2)

Flashing

Flashing

Shorted or open battery



OM-GRYPHON™/C-GRYPHON™ POWER/COMMUNICATION

Yellow LED

Meaning

ON Power

applied

OFF

Error in reading EEPROM parameters

Blinking

Transmission over the Host port


6.6 READING

DIAGRAMS

GRYPHON™ D130/M130

0

5

10

15

20

25

30

35

-15

-10

-5

0

5

10

15

Reading diagram at 25 °C and 300 lux ambient lighting

Reading Zones (10° skew angle)

(cm)

EAN13 M=1
0.33 mm
(13 mils)

CODE 39
0.50 mm
(20 mils)

0.13 mm
(5 mils)

164