5.2.5 Inter-Block
Delay
For the PEN Emulation interface, data are sent to the Host in fixed size blocks of 20
characters each. The inter-block delay parameter allows setting a delay between
each block sent to the Host.
5.3 DATA
FORMAT
The system always provides gun to host data communication using the following
message formatting:
Output Message from Gryphon™ Dx30 or Gryphon™ Mx30 Stand Alone Towards
Host
[Header] [Gun_Addr] [Gun_Addr_delimiter] ] [Code ID] [Code Length]
CODE
[Terminator]
[Items in square brackets are optional.]
Output Message from Gryphon™ Mx30 STAR-System™ Towards Host
[Header] [Code ID] [Code Length]
CODE
[Terminator]
[Items in square brackets are optional.]
5.3.1 Header/Terminator
Selection
The header/terminator selection is not effected by the reading of the restore default
code. In fact, header and terminator default values depend on the interface selection:
RS232:
no header, terminator CR-LF
WEDGE:
no header, terminator ENTER
These default values are always restored through the reading of RS232 or WEDGE
interface selection code, see chapter 2.