Dolby Laboratories DP503 User Manual
Page 67
A-3
A.1.6
TA Ctrl RS-232 Port, J107
DB-9 male connector.
Pin
Connection
Comments
1
DCD
direct connection to DTR
2
RX
asynchronous data in
3
TX
asynchronous data out
4
DTR
direct connection to DCD
5
Ground
6
DSR
direct connection to RTS
7
RTS
direct connection to DSR
8
NC
9
NC
A.1.7
Rem/Download RS-232 Port, J108
DB-9 female connector.
Pin
Connection
Comments
1
DCD
direct connection to DTR, DSR, and CTS
2
RX
asynchronous data out
3
TX
asynchronous data in
4
DTR
direct connection to DCD, DSR, and CTS
5
Ground
6
DSR
direct connection to DCD, DTR, and CTS
7
NC
8
CTS
direct connection to DCD, DTR, and DSR
9
NC
A.1.8
Status, J109
DB-9 male connector. 5 V CMOS levels.
Pin
Connection
Comments
1
Fault
Power supply or processor/memory fault
2
Test
Test tone selected
3
Digital Input
Valid AES/EBU or S/PDIF signal present
4
Lock
Phase locked loop locked to data clock
5
Overload Ch A
Channel A input signal at full scale
6
Overload Ch B
Channel B input signal at full scale
7
Remote
Remote control mode selected
8
NC
9
Ground
MAIN