5 switch nos. 7 & 8 - baud rate set – Dolby Laboratories DP503 User Manual
Page 30

3-6
3.5.2
Switch no. 6 - Mode of Operation: Normal/Download
The RS-232 port J108 Rem/Download can be used for 2 functions: upgrading of
the audio coding algorithm software whenever upgrades are introduced, and
remote control of the unit via a PC; in the latter instance upgrades can also be
performed via the remote control host.
Note:
When invoking the download mode or using the remote control feature, , the baud rate selection
switches S101-7 and S101-8 must also be set
Keep switch no. 6 in the Normal position when not performing a software
upgrade. Move the switch to the Download position when manually performing a
software upgrade.
Note:
See Appendix B for download instructions. RS-232 interface specifications are located in Appendix A.
3.5.5
Switch nos. 7 & 8 - Baud Rate Set
The combination of switches S101-7 and S101-8 select the choice of baud rate for
RS-232 port J108 Rem/Download, which can be used either for remote control or
software download as mentioned above.
Use the following table to set the baud rate:
SW101-7
SW101-8
Baud Rate
up
up
[9600]
up
down
19200
down
up
38400
down
down
57600
Note
See Appendix B for download instructions. See the documentation supplied with the remote control
software for remote control operation. RS-232 interface specifications are located in Appendix A.