IBQ.U.BLE

PROBABLE CAUSE AND REMEDY

L.

Display shows "DSFL".

1.

2.

3.

M.

Dryer does not respond to command

1.

at keyboard.

2.

3.

N.

Dryer runs, but heat indicating

light in L.E.D. does not come on.

1.

0.

Dryer motor starts, but gas valve

and glo-bar do not operate.

1.

2.

3.

4.

P.

Dryer motor starts, gas valve's

1.

primary coil operates, but glo-

|bar does not heat up.

2.

Q.

Dryer motor starts, gas valve and

1.

glo-bar operate, but gas does not

2.

come on.

3.

R.

All components are operating, but

gas is not ignited.

1.

Dryer sensor failed-check if

sensor is missing from holder.

Qieck wires leading to sensor

from connector to connector.

Replace temperature sensor.

Disconnect power.

Check flexable cable from key­

board to micro control unit.

In automatic mode, the problem

may be due to a faulty sensor

circuit. Refer to L above.

1. Computer defective.

Manual reset thermostat is open

reset.

Sail switch is open - readjust.

Hi-limit switch open - remove

connectors and shunt. MAKE TEST.

Replace switch and reconnect

wiring. BE SURE TO RECONNECT WIRES

TO SWITCH IF SWITCH IS NOT DEFECTIVE.

No voltage supply to gas valve - open

connection. Trace circuit with volt

or ohm meter. Repair connection or

wire.

Broken glo-bar - replace.

Faulty wire connection to either
glocoil or IR sensor.

Flame switch defective - replace.

Gas valve defective - replace.

Very low pressure - contact local

utility.

Improper position of glo-bar

adjust.

Low gas pressure - check manifold

pressure.

Adverse air disturbance around

front of burner could cause failure

of ignition - determine cause of

draft, eliminate it.

8-15