beautypg.com

Aligifent of timer, Impeller, V-belts – American Dryer Corp. AD-100 User Manual

Page 20

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

2.

To replace impeller motor

a.

Turn power off.

b.

Disconnect motor harness from motor.

c.

Remove nuts and washers holding the motor mount to the rear of

the dryer and pull motor mount away.

d.

Remove the two L.H. nuts on the motor shaft retaining the impeller

and work the impeller free from the motor shaft by means of a gear

puller to prevent damage to the motor shaft.

e.

Remove bolts holding motor to motor mount and replace with new

motor.

f.

Align motor with impeller face in plane with the motor mount at

no less than 3/16” clearance.

g.

Reinstall the motor mount, and reconnect motor harness.

IMPELLER:

The impeller is fastened to the motor shaft and should need no

replacement for the life of the dryer, (Page 9-11, Figure 10).

V-BELTS:

The V-belts should have a tension that permits approximately 1/2” of

displacement under a normal thumb pressure exerted at mid span. If too loose,

belts will slip; if too tight, belts will cause undue wear of the bearings.

Misaligned pulleys will cause excessive belt wear. Belts should be periodically

cleaned and treated with a proper conditioner for increased life.

1.

Belt tension adjustment - Tumbler to idler (See page

9-9).

a.

Back off nuts (No. 14) on

idler

adjustment

bolts.

b.

Tighten belts by turning both bolts (No. 11) evenly clockwise. (Turn

counter-clockwise to loosen belts).

c.

Check vertical plane of idler pulleys for parallel alignment with

tumbler pulleys and retighten bottom nuts.

2.

Belt tension adjustment - Idler to motor (See page 9-10).

a.

Loosen nuts (No. 18) on bolts holding motor mount to dryer frame.

b.

Raise or lower the motor mount for proper belt tension.

c.

Check motor shaft and pulley for parallel alignment with idler
shaft and pulleys.

d.

Retighten bolts.

ALIGIfENT OF TimER:

1.

Vertical alignment of tumbler (Page 9-8)

a.

Loosen top bolts (No. 9) on sides of bearing mount.

b.

Back off the lock nuts (No. 7) on the adjustment bolts (No. 6)

c.

Tighten the adjustment bolts evenly to raise the basket.

(Back off the bolts to lower basket)

c.

Retighten the lock nuts and retighten bolts on sides of
bearing mount.

8-8