Display codes, Ibeebatiire display, Auto cyclf range tripler – American Dryer Corp. AD-100 User Manual
Page 15
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

AUTO CYClf RANGE TRIPLER.
(Phase II Only) In the event that a dryness level
greater than 9 is required, opening Dip Switch Number 8 triples the dryness
level range, increasing the range total to 27.
IBEEBATIIRE DISPLAY
The displaying o£ operating temperature in the dryer through
the LEDS is available to the service technician. Program dryer into a normal
drying cycle and start. While the dryer is running, close Dip Switch Number 4.
Operating temperature can now be viewed through the display. On Phase II Computer
panels, the temperature can be viewed in either Farenheit or Centigrade. Dip
Switch Number 6 in the open position displays temperature in Farenheit, closed
displays temperature in centigrade.
DISPLAY CODES
FILL - Empty machine prior to data entry (AUTO/MANUAL dryer)
F_D__ - Display prior to data entry when auto cycle is selected or
indicates empty machine for auto only machine.
Ld - Load drying time (MANUAL mode)
Lc - Load cooling time (MANUAL mode)
F - Fabric selection (MANUAL mode)
Sr - Select reversing (reversing dryers with REVERSE/NO REVERSE
selectability)
Dr
- Machine is operating in drying mode.
Cl
- Machine is operating in cool down mode.
CC - Cycle complete, dryer has finished a complete cycle and
shut off.
DSFL - Dryer Sensor Circuit Failure. Most likely caused by loose wiring
connection at sensor bracket (Page 9-7, Figure 4).
DOOR - Door Switch Circuit Failure. Check wiring connections to door switch,
also is displayed if attempt is made to start dryer with door open.
It
8-3