background image

AUTO CYClf RANGE TRIPLER.

(Phase II Only) In the event that a dryness level

greater than 9 is required, opening Dip Switch Number 8 triples the dryness

level range, increasing the range total to 27.

IBEEBATIIRE DISPLAY

The displaying o£ operating temperature in the dryer through

the LEDS is available to the service technician. Program dryer into a normal

drying cycle and start. While the dryer is running, close Dip Switch Number 4.

Operating temperature can now be viewed through the display. On Phase II Computer

panels, the temperature can be viewed in either Farenheit or Centigrade. Dip

Switch Number 6 in the open position displays temperature in Farenheit, closed

displays temperature in centigrade.

DISPLAY CODES

FILL - Empty machine prior to data entry (AUTO/MANUAL dryer)
F_D__ - Display prior to data entry when auto cycle is selected or

indicates empty machine for auto only machine.

Ld - Load drying time (MANUAL mode)

Lc - Load cooling time (MANUAL mode)

F - Fabric selection (MANUAL mode)
Sr - Select reversing (reversing dryers with REVERSE/NO REVERSE

selectability)

Dr

- Machine is operating in drying mode.

Cl

- Machine is operating in cool down mode.

CC - Cycle complete, dryer has finished a complete cycle and

shut off.

DSFL - Dryer Sensor Circuit Failure. Most likely caused by loose wiring

connection at sensor bracket (Page 9-7, Figure 4).

DOOR - Door Switch Circuit Failure. Check wiring connections to door switch,

also is displayed if attempt is made to start dryer with door open.