SECTION Vili

SERVICING

GENERAL;

All electrical service should be made with POWER-OFF, Any service tests

requiring POWER-ON should be made only by fully qualified electricians.

mm

DOOR SWITCH:

This switch interrupts all power to the dryer when door is

opened. It is located in the lower right hand comer of the front panel, (page

9-4, Figure 13).

TO REPLACE OR ADJUST:

a.

Turn power off.

b.

Open lint door to gain access to switch behind front panel.

c.

Open main door and loosen hex nut holding switch to front panel.

d.

Disconnect leads to switch.

e.

Replace by reversing the procedure.

TUMBLER mTQR RELAY:

This relay controls the power to operate the tumbler motor.

It is located in the enclosure at the rear of the dryer. (Page 9-12, Figure 4).

Two relays operate alternately to reverse the motor rotation on dryers equipped

with this option,

TO REPLACE:

a.

Turn power off.

b.

Remove screws holding reset panel to dryer and remove panel.

c.

Disconnect harness from relay panel and remove bolts holding relay
panel to rear wall of enclosure.

d.

Remove relay panel.

e.

Disconnect leads to relay and remove relay from panel.

f.

Replace by reversing the procedure. Connect wiring to relay as shown

on schematic located inside the enclosure,

BLOVER NDTOR REI AY:

This relay controls the power to operate the blower motor.

It is located in the enclosure at the rear of the dryer (Page 9-12, Figure 9,

and Page 9-13, Figure 6),

TO REPLACE:

a.

Turn power off.

b.

Remove screws holding reset panel to dryer and remove panel.

c.

Disconnect harness from relay panel and remove bolts holding relay
panel to rear wall of enclosure.

d.

Remove relay panel.

e.

Disconnect leads to relay and remove relay from panel.

f.

Replace by reversing the procedure. Connect wiring to relay as shown

on schematic located inside the enclosure.

8