Conair Hopper Temperature Controller UGD031 User Manual
Page 97

A d d e n d u m l
A D - 1 5
S p e c i f i c a t i o n s : H o t A i r D r y e r ( H A D ) B l o w e r
A
B
C
Hot Air Dryer mode
l (HAD)
600 800
1000
1600
2400
3200
5000
RECOMMENDED MODEL HTC*
HTC-30B†
HTC-30B† HTC-30A†
HTC-60A†
HTC-90A†
HTC-120A†
HTC-120A†
Performance characteristics
Flow rate cfm
300
400
500
800
1200
1600
2500
Disc. pressure @flow rate
inches WC
‡
25 32
30
30
28
30
33
{mm} WC
‡
{635}
{813}
{762}
{762}
{711}
{762}
{838}
Motor Hp kW
5 {3.7}
7.5 {5.6}
7.5 {5.6}
10 {7.5}
15 {11.2}
25 {18.6}
Dimensions inches {cm} and weight lb {kg}
Outlet size selection (OD)
5
5
8
8
8
12
A - Height
42 {107}
42 {107}
42 {107}
42 {107}
42 {107}
42 {107}
B - Width
33 {84}
33 {84}
33 {84}
33 {84}
33 {84}
33 {84}
C - Length
39 {99}
39 {99}
42 {107}
42 {107}
80 {203}
82 {208}
Weight
Installed weight lb {kg}
§
250 {113}
320 {145}
380 {172}
500 {227}
700 {317}
900 {408}
Voltage Full Load Amps
400V/3 phase/50 Hz
9.1
13.2
13.2
16.8
25.2
40.8
460 V/3 phase/60 Hz
7.6
11
11
14
21
34
575 V/3 phase/60 Hz
6.1
9
9
11
17
27
Noise level
with standard soundproofing
< 90 dbA @ 5 ft.
SPECIFICATION NOTES:
* For single hopper system.
† The HTC model number reflects the kilowatts of each unit. For example, HTC-60 has a 60 kilowatt heater.
‡
The unit of measure WC is water column.
§
Weights are approximate.
Specifications may change without notice. Consult a Conair representative for the most current information.
TPDM024-0106