Conair Hopper Temperature Controller UGD031 User Manual
Page 40

POWER ON
1
888
888
2 sec All LEDs On
2
dC
004
2 sec Software Version
3
res
in
(Default Screen)
4
250
250
Process Setpoint and Actual Temp (Default Screen)
Press + or - to change setpoint.
Press Scroll Button for Process Deviation Alarm Setpoint (Dev)
5
5dEv
+ or - Deviation Band
Press + or - to change setpoint.
Press Scroll to enter the value
Process Screens
Process Protection Screens
Press Scroll Button and + key at the
Press Scroll Button and + key at the
same time for 2 sec to get in.
same time again for 2 sec to get in.
To get out at any time Press Scroll
To get out at any time Press Scroll
button and - key at the same time
button and - key at the same time
2 Min timer then return to the default screen
6
Pro
cES
16
Pro
tEc
Press Scroll again to view next screen
Press Scroll again to view next screen
7
375
Hi.L
Process High Limit
17
Act
250
Protect Temperature
Press Scroll again to view next screen
Press Scroll again to view next screen
8
3
Lbb
Process Loop Break Band
18
625
H.Al
Protect Hi Alarm SP
Press Scroll again to view next screen
Press Scroll again to view next screen
9
10
Lbt
Process Loop Break Time
19
10
H.dL
Protect Hi Alarm Delay
Press Scroll again to view next screen
Press Scroll again to view next screen
10
385
H.AL
Process High Alarm Setpoint
20
300
d.AL
Differential Alarm SP
Press Scroll again to view next screen
Press Scroll again to view next screen
11
50
Pb
Process Prop
21
80
d.dL
Differential Alarm Delay
Press Scroll again to view next screen
12
16
int
Process Integral
Press Scroll again to view next screen
Press Scroll again to view the first screen
13
2dEr
Process Derivative
Press Scroll again to view next screen
14
tun
OFF
Process Autotune
Press + Key to Start Autotune
Press Scroll again to view next screen
15
F
unt
Units degrees F or degrees C
Press + Key to toggle between F and C
Press Scroll again to view the first screen
Press Scroll Button again for Setback
Return Temperature Setpoint
5A
180
Srt
Press Scroll Button again for Process
Setback Temperature Setpoint
5B
140
PSt
Press Scroll to enter the value
(Optional)
Press + or - to change setpoint.
Press Scroll to enter the value
Press + or - to change setpoint.
4 - 4
l O p e r a t i o n