beautypg.com

Conair Hopper Temperature Controller UGD031 User Manual

Page 64

background image

5 - 2

l M a i n t e n a n c e

P r e v e n t a t i v e M a i n t e n a n c e
C h e c k l i s t

The HTC process air heater requires little maintenance. We recommend the fol-
lowing maintenance schedule and tasks.

• W h e n e v e r y o u c h a n g e m a t e r i a l o r p r o c e s s

Change the HTC setpoint if it must be changed.

• D a i l y o r w e e k l y a s n e e d e d

Inspect the inlet and outlet hoses.

Tighten the hose clamps if loose. Replace the hose if worn or damaged.

Inspect the filter (if equipped).

Clean or replace the filter as necessary.

• M o n t h l y o r a s o f t e n a s n e e d e d

Inspect the main power wires, heater wires and conduit, and RTD

probe wires for damage and wear.
Replace any damaged or worn wire or conduit.

Check for any damage to the control panel.

Replace if damaged.

Check for damage to the heater box.

Replace if damaged.

Clean dirt from exterior surfaces with a cloth dampened with water.