beautypg.com

Conair Hopper Temperature Controller UGD031 User Manual

Page 38

background image

Heaters

Startup /

Shutdown

For Startup:

1. With heaters in
Standby, turn on
blower or dryer.
2. Enable heaters.

For Shutdown:

1. Switch heaters to
Standby.
2. Wait 60 seconds
before turning off
blower or dryer.

Enable

Standby

4 - 2

l O p e r a t i o n

T h e H T C P r o c e s s A i r H e a t e r : C o n t r o l P a n e l D C

H e a t e r
E n a b l e / S t a n d b y

Also is used to reset
shut down alarms (see
“Troubleshooting”
Section 6) and to
“Autotune” the con-
troller (see
“Autotuning” Section
4).

S e t p o i n t

D i s p l a y

Shows the set-
point value.

I n c r e m e n t / D e c r e m e n t

B u t t o n s

Used to increase or decrease values.

A c t u a l

D i s p l a y

Shows the actual
temperature value.

A c k n o w l e d g e A l a r m B u t t o n

Under an alarm condition, pushing the
Acknowledge button once turns off the
horn and displays the alarm message.
Pushing the Acknowledge button a sec-
ond time turns off the alarm LED.

S c r o l l B u t t o n

Press to scroll
through the
closed loop menu
list. Pressing the
Scroll button
moves you down
the list.

This manual is related to the following products: