SECTION 6
CARING FOR YOUR MACHINE
REMOVING AND REPLACING BOBBIN CASE
CAUTION: Before cleaning or adjusting the
machine, remove plug from the socket
outlet.
• Raise presser foot and needle.
• Open slide plate and remove bobbin.
To remove the bobbin case, the needle
plate must be removed first.
• Lift needle plate (1) from right corner and
slide out from under foot.
TO REMOVE BOBBIN CASE
• Push lever (2) toward you until it stops,
and hold in this position.
• Lift bobbin case up and guide it out
toward you, as shown.
TO REPLACE THE BOBBIN CASE
• Push lever (2) toward you until it stops
and hold in this position.
• Guide bobbin case into place, making
sure block (3) is all the way under metal
bracket (4).
• Return lever (2) to locking position over
top of bobibn case.
NOTE: After locking case in place, be
sure it is not tight, but can move slightly.
• To replace needle plate, slide it under
pin (5) and push it to the left.
• Press needle plate down in palce.
• Insert bobbin and close slide plate.