Table 2 — dimensions, Physical data – Carrier 58GS User Manual
Page 2
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Table 2 — Dimensions
апЭ
Physical Data
MODEL NO. 58GS
125
SERIES
100
200
300
400
100
200
300
300
DIMENSIONS* (in.)
Width A
21
21
21
24-1/2
24-1/2
24-1/2
24-1/2
31-1/2
Depth B
28-1/2
28-1/2
28-1/2
28-1/2
28-1/2
28-1/2
28-1/2
28-1/2
Height!
Casing Only C
46-3/16
46-3/16
46-3/16
46-3/16
46-3/16
46-3/16
46-3/16
46-3/16
Air Openings
Supply D
19-3/8
19-3/8
19-3/8
22-7/8
22-7/8
22-7/8
22-7/8
29-7/8
Side Return (Ex 23-1/4) E
14-1/2
14-1/2
14-1/2
14-1/2
14-1/2
14-1/2
14-1/2
14-1/2
From Opening to Floor F
2-3/4
2-3/4
2-3/4
2-3/4
2-3/4
2-3/4
2-1/16
2-1/16
Bottom Return G
18-1/2
18-1/2
18-1/2
22
22
22
22
29
Flue (Equiv Round Pipe Dia ) J
5
5
5
5
6
6
6
7
FILTERt
Size
X
27-3/4 (in.)
19-3/8
19-3/8
19-3/8
22-7/8
22-7/8
22-7/8
22-7/8
29-7/8
RATINGS** (Natural Gas)
Input (1000 Btuh)
125
125
125
125
150
150
150
175
Bonnet Cap (1000 Btuh)
100
100
100
100
120
120
120
140
Temp Riseft (F)
70-100
65-95
60-90
45-75
65-95
65-95
45-75
60-90
Minimum Air for Heating
ESP (in wg)
0 20
—
—
-
0 20
—
—
—
Cfm
1089
1157
1234
1543
1388
1388
1851
1450
Max Air Cf/n (g) 0.5 in wg ESP
-
1230
1550
2110
—
1600
2110
1980
DD Blower Wheel (nom size — in
)
9x8
10x8
10x8
(2)10x6
10x10
10x10
(2)10x6
(2)10x6
HP-Type
1/5 Sh P
1/3Sh P
1/2 PSC
1/2PSC
1/3Sh P
1/2 PSC
1/2 PSC
1/2 PSC
BURNERS(No
)
5
5
5
5
6
6
6
7
APPROX SHIP WT(lb)
190
190
190
200
205
220
230
250
ELECTRICAL(S)
Unit Voltage (60-Hz)
115
115
115
115
115
115
115
115
Transformer (120-V/24-V)
20 va
40 va
40 va
40 va
20 va
40 va
40 va
40 va
A/C Blower Relay Rating
@ 120 V (amps)
None
13 8
13 8
13 8
None
138
13 8
13 8
Motor Full Load Amps
8
9
9
8 5
9 5
9 5
85
85
-
150
MODEL NO 58GS
050
075
100
SERIES
100
2P0
300
100
200
300
100
200
300
DIMENSIONS* (in.)
Width
A
14-3/16
14-3/16
14-3/16
14-3/16
14-3/16
14-3/16
17-1/2
17-1/2
21
Depth
В
28-1/2
28-1/2
28-1/2
28-1/2
28-1/2
28-1/2
28-1/2
28-1/2
28-1/2
Height!
Casing Only
c
46-3/16
46-3/16
46-3/16
46-3/16
46-3/16
46-3/16
46-3/16
46-3/16
46-3/16
Air Openings
Supply
D
12-9/16
12-9/16
12-9/16
12-9/16
12-9/16
12-9/16
15-7/8
15-7/8
19-3/8
Side Return (E x 23-1 /4)
E
14-1/2
14-1/2
14-1/2
14-1/2
14-1/2
14-1/2
14-1/2
14-1/2
14-1/2
From Opening to Floor
F
2-3/4
2-3/4
2-3/4
2-3/4
2-3/4
2-3/4
2-3/4
2-3/4
2-3/4
Bottom Return
G
11-11/16
11-11/16
11-1 1/16
11-11/16
11-1 1/16
11-11/16
15
15
18-1/2
Flue (Equiv Round Pipe Dia.)
J
4
4
4
4
4
4
5
5
5
FILTERt
Size X 27-3/4 (in.)
12-9/16
12-9/16
12-9/16
12-9/16
12-9/16
12-9/16
15-7/8
15-7/8
19-3/8
RATINGS** (Natural Gas)
Input (1000 Btuh)
50
50
50
75
75
75
100
100
100
Bonnet Cap (1000 Btuh)
40
40
40
60
60
60
80
80
80
Temp Rise!! (F)
40-70
40-70
35-65
55-85
55-85
45-75
65-95
60-90
45-75
Minimum Air for Heating
ESP (in. wg)
0 12
__
_
0.12
0.15
Cfm
673
673
740
793
793
925
925
987
1234
Max Air Cfm (g) 0 5 in. wg ESP
—
815
1170
—
800
1150
1155
1610
DD Blower Wheel (nom. size — in.)
9x6
9x6
10x6
9x6
9x6
10x6
9x7
10x7
10x8
HP-Type
1/IOSh P
1/6Sh P
1/3Sh.P
1/10Sh.P
1/6Sh.P
l/3Sh.P
1/6Sh.P
1/3Sh.P
1/2PSC
BURNERS(No)
2
2
2
3
3
3
4
4
4
APPROX SHIP WT(lb)
105
105
105
122
122
125
160
160
175
ELECTRICAL(S)
Unit Voltage (60-Hz)
115
115
115
115
115
115
115
115
115
Transformer (120-V/24-V)
20 va
40 va
40 va
20 va
40 va
40 va
20 va
40 va
40 va
A/C Blower Relay Rating
@ 120 V (amps)
None
138
138
None
138
138
None
13 8
13 8
Motor Full Load Amps
5
6
99
5
6
9 9
5 5
9 9
8 5
175
ESP
— External Static Pressure
DD
— Direct Drive
PSC
— Permanent Split Capacitor
Sh P
— Shaded Pole
*See certified prints for complete
dimensional specifications
tSee Furnace-Coil-Plenum-Adapter
Combinations table in Product Data
Digest Refer to 28 Series literaturefor
plenum dimensions
iDuralast permanent cleanable filters
See manufacturer's recommenda
tions for cleaning
**Ratings shown are for elevations up to
2000 ft above sea level For elevations
above 2000 ft, deduct 4% of input ca
pacity for each 1000 ft above sea level
ttDo n ot exc eed temperature ris e speci
fied on furnace nameplate Air tem
perature rise may be calculated using
the following formula:
bonnet capacity
0 24 X specific wt of air x 60 xcfm
bonnet capacity
1 08 X cfm
NOTE: Refer to Application Data litera
ture for complete fan performance
curves
CAOTiON, Air <^.vwy iSOO
i>3ce be or e combioatKi» of
one side ano bottom^ of boisam
on^y for reiurti a>r.