--------FIELD 24-VOLT WIRING
--------FIELD 115-, 208/230-, 460-VOLT WIRING
--------FACTORY 24-VOLT WIRING
--------FACTORY 115-VOLT WIRING
FOUR
WIRE
1-STAGE
THERMOSTAT
TERMINALS
FIELD-SUPPLIED
FUSED DISCONNECT
_BLK
.BLK
_____
WHT
WHT «
— i.. —4----------
__
—
“GND
m
115-VOLT FIELD-
AUXILIARY
SUPPLIED
J-BOX
FUSED
CONTROL
DISCONNECT
BOX
24-VOLT
TERMINAL
BLOCK
-■*rnw»-
-------•----------- j
—»rrrW>—
-
4
—
TGND
208/230- OR
,460-VOLT
THREE
PHASE
208/230-
VOLT
’SINGLE
PHASE
FURNACE
CONDENSING
UNIT
■TWO
WIRE NOTE: If any of the original wire,
as supplied, must be replaced, use
NOTE: Connect Y-terminal as
same type or equivalent wire,
shown for proper
operation.
A93378
Fig. 8—Heating and Cooling Appiication Wiring Diagram 1-Stage Thermostat and Condensing Unit
--------FIELD 24-VOLT WIRING
—FIELD 115-, 208/230-, 460-VOLT WIRING
--------FACTORY 24-VOLT WIRING
--------FACTORY 115-VOLT WIRING
SIX
WIRE
@
2-STAGE
THERMOSTAT
TERMINALS
FIELD-SUPPLIED
FUSED DISCONNECT
fiU<.
FURNACE
NOTE
208/230- OR
1.460-VOLT
'^THREE
PHASE
I
208/230-
IVOLT
f SINGLE
I PHASE
2-SPEED
CONDENSING
UNIT
THREE
WIRE NOTE: If any of the original wire,
Connect Y-terminal as
supplied, must be replaced, use
shown for proper
lYP® equivalent wire,
operation.
A93379
Fig. 9—Heating and Cooling Application Wiring Diagram 2-Stage Thermostat and Condensing Unit
furnaces. The horizontal portion of the venting system shall
maintain a minimum of 1/8-in. upward slope per linear ft and it
shall be rigidly supported every 5 ft or less with hangers or straps
to ensure that there will be no movement after installation.
This furnace may also be installed with a Category III vertical or
horizontal (sidewall) vent system using the accessory kit listed on
the vent label on the top plate of the furnace. This kit MUST be
used for Category III venting. Refer to the kit instructions for
detailed information about Category III venting.
A WARNING
DO NOT install a Category III vent system without the
accessory conversion kit. Category III vents without the
accessory kit will have nuisance shutdowns on draft safe
guard switch, and may cause vent and furnace component
failure resulting in property damage, personal injury, or death.
Only special gas vent pipe listed per UL 1738 for Category III
appliances may be used. See accessory kit instructions for allow
able vent pipe and fittings part numbers.