Table 1 — Electrical Data (&©^zt

MODEL

50QT

V/PH

OPER

VOLTAGE^

COMPR

IFM OFM

ELECTRIC

HEATER

AMPS

BRANCH CIRCUIT #1

(or Total Unit)t

BRANCH CIRCUIT #2

(When Used)t

Max Fuse or

HACR Ckt

Bkr Ampst

MCA

Max Fuse or

HACR Ckt

Bkr Ampst

MCA

Max

Min^*

LRA

RLA

FLA

FLA

AB

112300 II

208/230/1

254

187

37

6 8

1 5

1 0

9 4/12 5

18.0/20.8

25/30
35/40

22 8/26 6
33.5/37.0

115300

208/230/1

254

187

43

8 7

1 5

1 0

9 4/12 5

18 0/20 8

25/30
35/40

25 1/29 0
35.9/39.4

AB

118300 AD

AF

208/230/1

254

187

49

10 3

1 7

1 0

9 4/12 5

18 0/20 8

26 8/31 3

30/35
40/45
50/55

27 3/31 2
38 1/41 6
49 1/54 7

AD

124300 AF

AG

208/230/1

254

187

59

13 0

2 0

1 5

17 3/20 8

26 8/31 3
36 1/41.7

45/50
55/60

41 4/45 9
53.6/59.1

AD

130300 AF

AG

208/230/1

254

187

79

16 9

2 4

1 5

17 4/ 20 8

26 8/31 3
36 0/41 7

.....

50

/55 ^ 1 47.5/52J

1

♦Permissible limits of the voltage range at which units will

operate satisfactorily

fField wiring to be sized for NEC or local codes Use copper wire

only

^Maximum dual element fuse

♦♦Minimum voltage is 197 when outdoor ambient temperature

exceeds 105 F

NOTE: Dual values in this table (for example Electric Fleeter Amps

9 4/12 5) apply to 208- and 230-volt connections respectively

These units require 2 separate supply circuits

Refer to BOTFI branch circuit charts for complete
electrical data

FLA

— Full Load Amps

FIACR

— Heating, Air Conditioning

and Refrigeration

IFM

— Indoor Fan Motor

LRA

— Locked Rotor Amps

MCA—

Minimum Circuit

Amps

OFM

— Outdoor Fan Motor

RLA

— Rated Load Amps

♦INSPECT EQUIPMENT for damage prior to in­

stallation. To remove plastic wrapper, grasp bottom
and pull out until velcro strips separate. To remove
metal cover plate, remove 6 screws. Eile claim with
shipping

company

if

shipment

is

damaged

or

incomplete.

Leave chassis bolted to skid and replace metal

cover plate, plastic wrapper, and carton until ready
for installation into wall sleeve.

INSPECT

WALL

SLEEVE

installation

for

damage. Condensate drain pan must be free of
debris and installed in accordance with local build­
ing regulations. Electrical connector on left side of

sleeve should be free of dirt, grease, paint, etc.

Connector must be properly wired before chassis
installation. Duct connection panel must be level
and duct connections complete. Do not rest weight
of ductwork on duct connector panel. Inspect name­
plate on sleeve to ensure wire and fuse sizing is

correct for model size to be installed.

At ^

-i

Fig. 1 — Chassis with Indoor Plastic Wrapper

©