UNIT
SIZE
48SS
018
024,
030
036
042
048
060
DRY COIL AIR DELIVERY* - VERTICAL DISCHARGE
(Deduct 10% for 208 v)
230 AND 460 VOLT VERTICAL DISCHARGE
MOTOR
SPEED
E xternal St
atic Press ure (In. w
g)
0.0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
Low
Watts
_
295
251
223
201
176
149
124
_
_
_
- - - - -
-
—
- - -
Cfm
—
821
817
753
665
536
343
164
—
—
—
High
Watts
401
376
346
322
294
272
250
229
219
_
_
^Cfm "
1334
" 1253 "
1Í28
996
816
658
461
246
167
—
—
Low
Watts
_
285
284
282
278
274
270
261
251
244
230
- - - -
- -
-
-
- - — - -
-
----
- _ - _
Cfm
—
798
761
727
682
634
581
525
450
371
304
Med
Watts
—
378
371
368
362
357
343
332
315
301
283
Cfm
-
1011
982
948
906
858
771
703
597
492
387
High
Watts
—
520
511
487
472
451
431
411
385
362
341
Cfm
—
1342
1289
1237
1181
1106
1007
892
745
610
471
Low
Watts
-
460
439
423
898
379
349
322
297
270
246
Cfm
—
1191
1136
1081
1005
907
795
687
579
471
349
Med
Watts
-
511
492
470
450
420
392
364
332
308
275
Cfm
-
1316
1244
1178
1104
1005
891
784
657
535
389
High
Watts
—
655
631
603
584
552
522
492"
459
433
398
Cfm
—
1541
1458
1367
1292
1178
1053
920
806
662
509
Low
Watts
—
637
612
587
560
536
493
455
-
-
—
Cfm
—
1500
1450
1405
1350
1290
1200
1105
~
—
—
High
Watts
790
750
700
699
639
608
574
547
—
—
Cfm
-
1750
1625
1604
1509
1421
1323
1221
1094
-
-
Low
Watts
-
847
784
746
708
646
609
563
516
-
-
Cfm
-
1995
1901
1822
1730
1580
1477
1319
1178
—
-
High
Watts
-
-
909
852
820
801
751
687
639
—
—
Cfm
-
-
2018
1896
1814
1729
1582
1380
1220
—
—
Low
Watts
-
970
952
928
905
880
847
804
760
-
-
Cfm
-
2075
2054
2024
1994
1945
1890
1830
1762
—
—
Med
Watts
-
-
1291
1247
1195
1076
1025
970
921
833
810
Cfm
~
-
2395
2348
2291
2164
2099
2022
1950
1827
1804
High
Watts
-
1490
1400
1312
1270
1219
1161
1104
1045
985
930
Cfm
-
2530
2475
2420
2355
2289
2223
2150
2079
2008
1932
*Air delivery values are based on operating voltage of 230 v or 460 v, dry coil, without filter
Deduct wet coil and filter pressure drops to obtain external static pressure available for ducting
NOTES
1 Do not operate the unit at a cooling airflow that is less than 350 cfm for each 12,000 Btuh of
rated cooling capacity Evaporator coil frosting may occur at airflows below this point
2 Dashes indicate portions of table that are beyond the blower motor capacity or are not
recommended
17