TROUBLESHOOTING
SYMPTOM AND
PROBABLE CAUSE
PROBABLE REMEDY
COMPRESSOR DOES NOT RUN
Opening in Power Circuit
1 Control off
2. Blown fuse
3 Defective wiring
4 Defective service cord
5 Loose electrical connections
6 Faulty switches, thermostat, or fan
1 Reset control button
2 Replace fuse
3 Replace wiring
4 Replace service cord
5 Tighten connections
6 Replace defective component
Compressor Power Supply Open
1 Loose leads at compressor terminals
2 Defective motor overload switch
3 Defective capacitor
4. Open compressor windings
5. Seized compressor
1 Tighten leads
2 Replace switch
3 Replace capacitor
4 Replace compressor
5 Replace
compressor
COMPRESSOR RUNS BUT CYCLES
Fan Operating Erratically
1 Loose lead at fan motor
2. Defective or burned out motor
3 Outdoor air restricted or recirculating
4 Overcharge or noncondensables in system
5 Restricted discharge line
6 Defective motor overload switch
1 Tighten lead
2 Repair or replace motor
3 Check for dirty filter, proper clearances around unit —
remove any obstructions
4 Recover refrigerant, evacuate and recharge system according to
nameplate specifications
5. Check for obstruction in line, replace tubing if required
6 Replace switch
Cycles on Compressor Overload
1 Defective run capacitor
2 Defective compressor bearings or valves
3 Greatly restricted indoor air (Iced evaporator coil)
4 Low refrigerant charge
5 Evaporator capillary restricted
6 Liquid line restricted
7. Compressor hot
8 Weak or inconsistent iine power
1 Replace capacitor
2 Replace compressor
3 Defrost evaporator coil
4 Add charge according to approved method
5 Replace capillary
6
Replace strainer
7 Verify refrigerant charge
8 Check line voltage at time of compressor start-up
INSUFFICIENT COOLING
Cooling Air Not Adequate
1 Dirty filter or coil
2. Iced evaporator coil (slightly low refrigerant charge)
3 Defective fan motor
1 Clean as required
2 Recharge
3 Replace fan motor
Condenser Air Not Adequate
1 Condenser air restricted
2 Dirty coil
3 Defective fan motor
1 Check for obstructions and dirty filter Remedy as required
2 Clean coil
3 Replace fan motor
Unit Undersized
Re-evaluate unit for proper capacity
Air Leakage
Check caulking around sleeve Repair if necessary
Capillary Restricted
Replace capillary
Compressor Flooding
1 Unit overcharged
2 Low evaporator airflow
1 Recover refrigerant, evacuate and recharge system according to
nameplate specifications
2 Clean filter and/or evaporator coil
AIR SWEEP NOT WORKING
1 Cam disengaged from lever
2 Air sweep motor failure
1 Activate motor and allow cam to re-engage
2 Replace motor
MESSAGE DISPLAY CODES
d
CP
PF
01
■
Unit in Dehumidification mode
Unit in Compressor Protection mode Allow 2 minutes for restart
Power failure
Room air thermistor failure