fsOPF I

Electrical data (cont)

50DF034 and 044

MODEL

NOMINAL

VOLTS/PH/HZ

50DF034

208-230/3/60

50DF034

'Ì60/3/60

50DF034

575/3/60

50DF044

208-230/3/60

50DF044

460/3/60

50DF044

575/3/60

VOLTAGE

RANGE

Min Max

187

414

518

187

414

518

254

508

660

254

508

632

COMPR

NO. 1

RLA LRA

63 5

27 5

22 0

80

37 0

30 0

266

120

96

345

173

120

COMPR

NO. 2

RLA LRA

63 5

27 5

22

0

80

37 0

30 0

266

120

96

345

173

120

OUTDOOR

FAN

MOTORS

Qty

FLA

7 6

(ea)

3 3

(ea)

2 7

(ea)

7 6

(ea)

33

(ea)

2 7

(ea)

INDOOR

EXHAUST

POWER SUPPLY*

FAN

FAN

HEATERS

Circuit

Circuit

MOTOR

MOTOR

No 1

No. 2

Hp

FLA

Hp

FLA

Kw

FLA

MCA

MOCP

MCA

MOCP

10

30 8

_

197

250

___

10

30 8

3

11

208

250

15

46 0

__

-

212

250

10

30 8

45- 54 9

125-138

197-211

250-250

10

30 8

_

75- 91 5

208-230

197-197

250-250

156-173

175-200

10

30 8

105-128 1

291-322

197-211

250-250

208-230

225-250

15

46 0

3

11

223

250

10

30 8

3

11

45- 54 9

125-138

208-211

250-250

10

30 8

3

11

75- 91 5

208-230

208-208

250-250

156-173

175-200

10

30 8

3

11

105-128 1

291-322

208-211

250-250

208-230

225-250

15

46 0

45- 54 9

125-138

214-230

300-300

__

15

46 0

75- 91 5

208-230

212-212

250-250

156-173

1 75-200

15

46 0

105-128 1

291-322

214-230

300-300

208-230

225-250

15

46 0

3

11

45- 54 9

125-138

223-230

300-300

15

46 0

3

11

75- 91 5

208-230

223-223

250-250

156-173

175-200

15

46 0

3

11

105-128 1

291-322

223-230

300-300

208-230

225-250

10

MO

86

110

___

10

140

3

48

__

91

110

— -

15

21 0

_

93

110

10

140

54 9

69

104

125

10

140

91 5

115

162

150

10

140

128 1

161

219

200

15

20 0

3

48

98

125

10

140

3

48

54 9

69

104

125

10

140

3

48

91 5

115

162

150

10

140

3

48

128 1

161

219

200

-

15

21 0

54 9

69

113

150

15

21 0

_

91 5

115

170

175

15

21 0

128 1

161

228

225

15

21 0

3

48

54 9

69

113

150

15

21 0

3

4 8

91 5

115

170

175

15

21 0

3

4 8

128 1

161

228

225

10

11 0

69

90

10

11 0

3

3 9

73

90

15

75

90

3

39

79

100

15

46 0

__

249

300

15

46 0

3

11

271

350

20

53 5

263

300

15

46 0

-

60- 73 2

166-184

265-288

350-350

-

15

46 0

-

90-109 8

249-276

249-249

300

208-230

275-250

15

46 0

135-164 7

374-414

265-288

350-350

259-288

300-300

20

53 5

3

11

285

350

15

46 0

3

11

60- 73 2

166-184

271-288

350-350

-

15

46 0

3

11

90-109 8

249-276

271-271

350-350

208-230

225-250

15

46 0

3

11

135-164 7

374-414

271-288

350-350

259-288

300-300

20

53 5

60- 73 2

166-184

283-305

350-350

20

53 5

90-109 8

249-276

263-263

300-300

208-230

225-250

20

53 5

135-164 7

374-414

283-305

350-350

259-288

300-300

20

53 5

3

11

60- 73 2

166-184

285-305

350-350

__

20

53 5

3

11

90-109 8

249-276

285-305

350-350

208-230

225-250

20

53 5

3

11

135-164 7

374-414

285-305

350-350

259-288

300-300

15

21 0

115

150

15

21 0

3

48

__

124

150

20

27 0

121

150

15

21 0

73 2

92

142

175

15

21 0

109 8

138

199

200

15

21 0

164 7

207

142

175

144

150

20

27 0

3

48

130

150

15

21 0

3

48

73 2

92

142

175

15

21 0

3

48

109 8

138

199

200

15

21 0

3

48

164 7

207

142

175

144

150

20

27 0

73 2

92

149

200

___

20

27 0

109 8

138

207

225

20

27 0

164 7

207

149

200

144

150

20

27 0

3

48

73 2

92

149

200

20

27 0

3

48

109 8

138

207

225

20

27 0

3

48

164 7

207

149

200

144

150

15

154

93

no

___

--

15

154

3

39

101

125

20

20

98

125

___

--

20

20

3

39

106

125

i

COMPR —

Compressor

FLA

— Full Load Amps

Hp

— Nominal Horsepower

Kw

— Kilowatts

LRA

— Locked Rotor Amps

LEGEND

MCA —Minimum Circuit Ampacity

MOCP — Maximum Overcurrent Protection
RLA — Rated Load Amps
*Fuse only

14

NOTES;
1 All outdoor fan motors are single-phase motors

2 All heaters are 3-phase assemblies
3 Circuit no 2 is provided as indicated; total unit MCA equals

the sum of circuit no 1 MCA plus circuit no 2 MCA