beautypg.com

Set deadband, Proportional effect – Wilkerson ER08 User Manual

Page 6

background image

Parameter Number 39 – Displays Current Software Version

Step

1

2

3

Press

3-6 seconds

Until

Display

Reads

Flashing Decimal

Description

Accesses

changeable

parameters.

Accesses

parameter no. 39.

Displays current

parameter value.

XXX = current

software version

40mm & 60mm Proportional Regulator

2R210

6

Set Deadband

Deadband is the minimum limit of accuracy at which the regulator is set for normal operation. The displayed value is X 10 mbar
and has a range between 4 (40 mbar) and 40 (400 mbar).

Parameter Number 13 – Set Deadband (P20 Must be Set to 0)

Step

1

2

3

4

5

Press

3-6 seconds

Until

Display

Reads

Flashing Decimal

Flashing Decimal

(value between

4 and 40)

Flashing

Description

Accesses

changeable

parameters.

Accesses

parameter no. 13.

Displays current

parameter value.

Incremental

value is

x 10 mbar

Edits parameter.

Accepts and saves

new parameter

setting.

Sequences to next

parameter.

or

or

or

Parameter Number 21 – Set Proportional Effect (P20 Must be Set to 0)

Step

1

2

3

4

5

Press

3-6 seconds

Until

Display

Reads

Flashing Decimal

Flashing Decimal

(value between

5 and 100)

Flashing

Description

Accesses

changeable

parameters.

Accesses

parameter no. 21.

Displays current

parameter value.

Edits parameter.

5 = fastest

regulation

100 = slowest

regulation.

Accepts and saves

new parameter

setting.

Sequences to next

parameter.

Proportional Effect

Sets the speed at which the regulator adjusts either filling or exhausting. The displayed value has a range between 5 (fastest
regulation) and 100 (slowest regulation).

or