Wilkerson SF2 User Manual

Symbols installation, Introduction, Application limits

background image

Installation & Service Instructions:
83-948-000

SF1 & SF2 Particulate Filters

ISSUED: May, 2008
Supersedes: August, 2006

Doc.# 83948000, EN# 080328, Rev. 5

Symbols

Installation

1. The filter should be installed with reasonable accessibility for

service whenever possible – repair service kits are available.

Keep pipe or tubing lengths to a minimum with inside clean

and free of dirt and chips. Pipe joint compound should be used

sparingly and applied only to the male pipe – never into the

female port. Do not use PTFE tape to seal pipe joints – pieces

have a tendency to break off and lodge inside the unit, possibly

causing malfunction. Also, new pipe or hose should be installed

between the filter and equipment being protected.

2. The upstream pipe work must be clear of accumulated dirt and

liquids.

3. Select a filter location as close as possible to the equipment

being protected and upstream of any pressure regulator.

4. Install filter so that air flows in the direction of arrow on body.
5. Install filter vertically with bowl drain mechanism at the bottom.

Free moisture will thus drain into the sump “quiet zone” at the

bottom of the bowl.

Introduction

Follow these instructions when installing, operating, or servicing

the product.

Application Limits

These products are intended for use in general purpose

compressed air systems only.
Maximum Recommended Pressure Drop:

kPa PSIG

bar

Particulate Filter

70

10

0.7

Operating Pressure Maximum

kPa PSIG

bar

Bowl w/ Twist Drain / No Sight Gauge

2068

300

21.0

Bowl w/ Autodrain / No Sight Gauge

1210

175

12.1

Bowl w/ Twist Drain and Sight Gauge

1700

250

17.0

Bowl w/ Autodrain and Sight Gauge

1210

175

12.1

Operating Temperature Range:
SF1 –

Manual Twist Drain

0°F to 180°F (-18°C to 82°C)

Auto Pulse Drain

32°F to 150°F (0°C to 66°C)

SF2 –
Manual Twist Drain (D)

0°F to 180°F (-18°C to 82°C)

Manual Twist Drain (W)

0°F to 150°F (-18°C to 66°C)

Automatic Float Drain

32°F to 150°F (0°C to 66°C)

Note: Air must be dry enough to avoid ice formation at temperatures

below 32°F (0°C).

Richland, MI 49083

Tel: (269) 629-5000

WARNING

To avoid unpredictable system behavior that can cause personal injury

and property damage:

• Disconnect electrical supply (when necessary) before installation,

servicing, or conversion.

• Disconnect air supply and depressurize all air lines connected to this

product before installation, servicing, or conversion.

• Operate within the manufacturer’s specified pressure, temperature,

and other conditions listed in these instructions.

• Medium must be moisture-free if ambient temperature is below

freezing.

• Service according to procedures listed in these instructions.
• Installation, service, and conversion of these products must be

performed by knowledgeable personnel who understand how

pneumatic products are to be applied.

• After installation, servicing, or conversion, air and electrical supplies

(when necessary) should be connected and the product tested for

proper function and leakage. If audible leakage is present, or the

product does not operate properly, do not put into use.

• Warnings and specifications on the product should not be covered by

paint, etc. If masking is not possible, contact your local representative

for replacement labels.

!

WARNING

FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE

PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS

CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.
This document and other information from The Company, its subsidiaries

and authorized distributors provide product and/or system options for further

investigation by users having technical expertise. It is important that you

analyze all aspects of your application, including consequences of any failure

and review the information concerning the product or systems in the current

product catalog. Due to the variety of operating conditions and applications for

these products or systems, the user, through its own analysis and testing, is

solely responsible for making the final selection of the products and systems

and assuring that all performance, safety and warning requirements of the

application are met.
The products described herein, including without limitation, product features,

specifications, designs, availability and pricing, are subject to change by The

Company and its subsidiaries at any time without notice.

EXTRA COPIES OF THESE INSTRUCTIONS ARE AVAILABLE FOR INCLUSION

IN EQUIPMENT / MAINTENANCE MANUALS THAT UTILIZE THESE PRODUCTS.

CONTACT YOUR LOCAL REPRESENTATIVE.

!

Safety Guide

For more complete information on recommended application

guidelines, see the Safety Guide section of Pneumatic Division

catalogs or you can download the

Pneumatic Division Safety

Guide at: www.wilkersoncorp.com

Automatic

Drain

Filter

w/Manual

Drain

This manual is related to the following products: