Wilkerson SM2 User Manual
Introduction, Application limits, Warning
Installation & Service Instructions:
83-947-000
SM1 & SM2 Coalescing Filter
ISSUED: May, 2008
Supersedes: August, 2006
Doc.# 83947000, EN# 080328, Rev. 4
Introduction
Follow these instructions when installing, operating, or servicing
the product.
Application Limits
These products are intended for use in general purpose
compressed air systems only.
Maximum Recommended Pressure Drop:
kPa PSIG
bar
Coalescing Filter
70
10
0.7
Operating Pressure Maximum
kPa PSIG
bar
Bowl w/ Twist Drain / No Sight Gauge 2068
300
21.0
Bowl w/ Autodrain / No Sight Gauge
1210
175
12.1
Bowl w/ Twist Drain and Sight Gauge
1700
250
17.0
Bowl w/ Autodrain and Sight Gauge
1210
175
12.1
Operating Temperature Range:
SM1 –
Manual Twist Drain
0°F to 180°F (-18°C to 82°C)
Auto Pulse Drain
32°F to 150°F (0°C to 66°C)
SM2 –
Manual Twist Drain
(Without Sight Gauge)
0°F to 180°F (-18°C to 82°C)
Manual Twist Drain
(With Sight Gauge)
0°F to 150°F (-18°C to 66°C)
Automatic Float Drain
32°F to 150°F (0°C to 66°C)
Note: Air must be dry enough to avoid ice formation at temperatures
below 32°F (0°C).
WARNING
To avoid unpredictable system behavior that can cause personal injury
and property damage:
• Disconnect electrical supply (when necessary) before installation,
servicing, or conversion.
• Disconnect air supply and depressurize all air lines connected to this
product before installation, servicing, or conversion.
• Operate within the manufacturer’s specified pressure, temperature,
and other conditions listed in these instructions.
• Medium must be moisture-free if ambient temperature is below
freezing.
• Service according to procedures listed in these instructions.
• Installation, service, and conversion of these products must be
performed by knowledgeable personnel who understand how
pneumatic products are to be applied.
• After installation, servicing, or conversion, air and electrical supplies
(when necessary) should be connected and the product tested for
proper function and leakage. If audible leakage is present, or the
product does not operate properly, do not put into use.
• Warnings and specifications on the product should not be covered by
paint, etc. If masking is not possible, contact your local representative
for replacement labels.
!
WARNING
FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE
PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS
CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.
This document and other information from The Company, its subsidiaries
and authorized distributors provide product and/or system options for further
investigation by users having technical expertise. It is important that you
analyze all aspects of your application, including consequences of any failure
and review the information concerning the product or systems in the current
product catalog. Due to the variety of operating conditions and applications for
these products or systems, the user, through its own analysis and testing, is
solely responsible for making the final selection of the products and systems
and assuring that all performance, safety and warning requirements of the
application are met.
The products described herein, including without limitation, product features,
specifications, designs, availability and pricing, are subject to change by The
Company and its subsidiaries at any time without notice.
EXTRA COPIES OF THESE INSTRUCTIONS ARE AVAILABLE FOR INCLUSION
IN EQUIPMENT / MAINTENANCE MANUALS THAT UTILIZE THESE PRODUCTS.
CONTACT YOUR LOCAL REPRESENTATIVE.
!
Richland, MI 49083
Tel: (269) 629-5000
Symbols
Coalescing FIlter
Coalescing Filter
w/ Manual Drain
w/ Auto Drain
Installation
1. The filter should be installed with reasonable accessibility for
service whenever possible – repair service kits are available.
Keep pipe or tubing lengths to a minimum with inside clean
and free of dirt and chips. Pipe joint compound should be used
sparingly and applied only to the male pipe – never into the
female port. Do not use PTFE tape to seal pipe joints – pieces
have a tendency to break off and lodge inside the unit, possibly
causing malfunction. Also, new pipe or hose should be installed
between the filter and equipment being protected.
2. The upstream pipe work must be clear of accumulated dirt and
liquids.
3. Select a filter location as close as possible to the equipment
being protected and upstream of any pressure regulator.
4. A 5 micrometer pre-filter is recommended to protect the high
efficiency filter and to prolong the element's life.
5. Install filter so that air flows in the direction of arrow on body.
6. Install filter vertically with bowl drain mechanism at the bottom.
Free moisture will thus drain into the sump “quiet zone” at the
bottom of the bowl.
Safety Guide
For more complete information on recommended application
guidelines, see the Safety Guide section of Pneumatic Division
catalogs or you can download the
Pneumatic Division Safety
Guide at: www.wilkersoncorp.com