Application limits, Symbols installation, Operation

background image

Application Limits

These products are intended for use in general purpose
compressed air systems only.
Operating Pressure:

kPa

PSIG

bar

Maximum Inlet Pressure

1720

250

17.2

Ambient Temperature Range:

0°C to 80°C (32°F to 175°F)

Symbols

Installation

1. The regulator should be installed with reasonable accessibility

for service whenever possible - repair service kits are available.

Keep pipe and tubing lengths to a minimum with inside clean

and free of dirt and chips. Pipe joint compound should be used

sparingly and applied only to the male pipe - never into the

female port. Do not use PTFE tape to seal pipe joints - pieces

have a tendency to break off and lodge inside unit, possibly

causing malfunction.

2. Install regulator so that air flow is in the direction of arrow.

Installation must be upstream (high pressure) side and as

close to the devices it is to service (valve, cylinder, tool, etc.).

Mounting may be in any position.

3. Gauge ports are located on both sides of the regulator body.

It is necessary to install a gauge or pipe plugs into each port

during installation.

4. For protection against rust, pipe scale, and other foreign matter,

install a filter on the upstream (high pressure) side as close to

the regulator as possible.

Operation

1. Before turning on the air supply, turn the adjusting knob or

“T” handle counterclockwise until compression is released

from the control spring. Then turn on air supply and adjust

regulator to desired secondary pressure by turning adjusting

knob/handle clockwise. This permits pressure to build up slowly,

preventing any unexpected operation of the valve, cylinders,

tools, etc., attached to the line. Adjustment to desired secondary

pressure can be made only with primary pressure applied to

the regulator.

2. To decrease regulator pressure setting, always reset from a

pressure lower than the final setting desired. For example,

lowering the secondary pressure from 550 to 410 kPa (80 to 60

psig) is best accomplished by dropping the secondary pressure

to 350 kPa (50 psig), then adjusting upward to 410 kPa (60

psig).

Push the adjusting knob down to lock the pressure setting. On

the “T” handle units, tighten the hex nut against the bonnet to

lock setting.

Service

CAuTIOn:

SHUT OFF AIR SUPPLY and exhaust the primary and

secondary pressure before disassembling regulator unit.

(Turning the knob/handle counterclockwise reduces

regulator’s setting, but does not vent downstream pressure

on non-relieving regulators.)

Relieving Regulator

Adjustable

non-Relieving Regulator

Adjustable

Pneumatic Division
Richland, Michigan 49083
269-629-5000

Introduction

Follow these instructions when installing, operating, or servicing
the product.

WARnInG

To avoid unpredictable system behavior that can cause personal injury

and property damage:
• Disconnect electrical supply (when necessary) before installation,

servicing, or conversion.

• Disconnect air supply and depressurize all air lines connected to this

product before installation, servicing, or conversion.

• Operate within the manufacturer’s specified pressure, temperature,

and other conditions listed in these instructions.

• Medium must be moisture-free if ambient temperature is below

freezing.

• Service according to procedures listed in these instructions.
• Installation, service, and conversion of these products must be

performed by knowledgeable personnel who understand how

pneumatic products are to be applied.

• After installation, servicing, or conversion, air and electrical supplies

(when necessary) should be connected and the product tested for

proper function and leakage. If audible leakage is present, or the

product does not operate properly, do not put into use.

• Warnings and specifications on the product should not be covered by

paint, etc. If masking is not possible, contact your local representative

for replacement labels.

!

WARnInG

FAILuRE OR IMPROPER SELECTIOn OR IMPROPER uSE OF THE

PRODuCTS AnD/OR SYSTEMS DESCRIBED HEREIn OR RELATED ITEMS

CAn CAuSE DEATH, PERSOnAL InJuRY AnD PROPERTY DAMAGE.
This document and other information from The Company, its subsidiaries

and authorized distributors provide product and/or system options for further

investigation by users having technical expertise. It is important that you

analyze all aspects of your application, including consequences of any failure

and review the information concerning the product or systems in the current

product catalog. Due to the variety of operating conditions and applications for

these products or systems, the user, through its own analysis and testing, is

solely responsible for making the final selection of the products and systems

and assuring that all performance, safety and warning requirements of the

application are met.
The products described herein, including without limitation, product features,

specifications, designs, availability and pricing, are subject to change by The

Company and its subsidiaries at any time without notice.

EXTRA COPIES OF THESE InSTRuCTIOnS ARE AVAILABLE FOR InCLuSIOn

In EQuIPMEnT / MAInTEnAnCE MAnuALS THAT uTILIZE THESE PRODuCTS.

COnTACT YOuR LOCAL REPRESEnTATIVE.

!

WARnInG

Product rupture can cause serious injury.

Do not connect regulator to bottled gas.

Do not exceed maximum primary pressure rating.

!

Safety Guide

For more complete information on recommended application
guidelines, see the Safety Guide section of Pneumatic Division
catalogs or you can download the

Pneumatic Division Safety

Guide at: www.parker.com/safety

Installation & Service Instructions
2R300C
1" Regulator Series
ISSuED: August, 2006
Supersedes: April, 2006

Doc. # 2R300C, ECn #060900, Rev 8

!