beautypg.com

Wilkerson H12 User Manual

Introduction, Application limits, Symbols installation

background image

Introduction:

Follow these instructions when installing, operating, or servicing
the product.

Application Limits

These products are intended for use in general purpose
compressed air systems only.

Operating Pressure:

kPa

PSIG

bar

Maximum Inlet Pressure

1734

250

17.3

Ambient Temperature Range: 0°C to 80°C (32°F to 175°F)

Symbols

Installation

1. The regulator should be installed with reasonable

accessibility for service whenever possible – repair service
kits are available. Keep pipe or tubing lengths to a minimum
with inside clean and free of dirt and chips. Pipe joint
compound should be used sparingly and applied only to
the male pipe – never into the female port. Do not use
PTFE tape to seal pipe joints – pieces have a tendency to
break off and lodge inside the unit, possibly causing
malfunction.

2. Install regulator so that air flow is in the direction of arrow.

Installation must be on the upstream (high pressure) side
and as close to the devices it is to service (lubricator,
valve, cylinder or tool). Mounting may be in any position.

3. Gauge ports are located on both sides of the regulator

body for your convenience. It is necessary to install a
gauge or socket pipe plug into each port during installation.

Relieving

Non-Relieving

Operation

1. Before turning on the air supply, turn the adjusting knob on

the pilot (master) regulator until compression is released
from the pressure control spring. Turn on air supply to the
master regulator and the pilot controlled regulator. Adjust
the downstream pressure by turning adjusting knob on the
master regulator until the desired downstream pressure is
obtained.

2. To decrease regulated pressure setting, always reset from

a pressure lower than the final setting required. Example,
lowering the secondary pressure from 80 PSIG to 60 PSIG
is best accomplished by dropping the secondary pressure
to 50 PSIG, then adjusting upward to 60 PSIG.

Service

CAUTION: SHUT OFF AIR SUPPLY

and depressurize the

unit. Turn the adjusting knob on the master regulator until
pilot pressure is relieved on the pilot controlled regulator.

A. Use the following procedure to service the regulator

piston:

1. Unscrew the threaded collar and remove the bonnet assembly.

2. Disassemble, clean and carefully inspect parts for wear or

damage. If replacement is necessary, use parts from the
service kits.

3. Lubricate bonnet bore with grease found in kit. Carefully

install piston seals as shown in assembly drawing. The V
side of each seal must be installed facing the end of the
piston. Install vent seal if repairing a relieving regulator. Install
piston assembly into bonnet

4. Assemble bonnet assembly to body and tighten threaded

collar per Figure 1.

!

!

WARNING

To avoid unpredictable system behavior that can cause personal
injury and property damage:

• Disconnect electrical supply (when necessary) before installation,

servicing, or conversion.

• Disconnect air supply and depressurize all air lines connected to

this product before installation, servicing, or conversion.

• Operate within the manufacturer’s specified pressure, temperature,

and other conditions listed in these instructions.

• Medium must be moisture-free if ambient temperature is below

freezing.

• Service according to procedures listed in these instructions.

• Installation, service, and conversion of these products must be

performed by knowledgeable personnel who understand how
pneumatic products are to be applied.

• After installation, servicing, or conversion, air and electrical

supplies (when necessary) should be connected and the product
tested for proper function and leakage. If audible leakage is present,
or the product does not operate properly, do not put into use.

• Warnings and specifications on the product should not be covered

by paint, etc. If masking is not possible, contact your local
representative for replacement labels.

WARNING

FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF
THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR
RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND
PROPERTY DAMAGE.
This document and other infor mation from The Company, its
subsidiaries and authorized distributors provide product and/or system
options for further investigation by users having technical expertise. It
is important that you analyze all aspects of your application, including
consequences of any failure and review the information concerning
the product or systems in the current product catalog. Due to the
variety of operating conditions and applications for these products or
systems, the user, through its own analysis and testing, is solely
responsible for making the final selection of the products and systems
and assuring that all performance, safety and warning requirements
of the application are met.
The products described herein, including without limitation, product
features, specifications, designs, availability and pricing, are subject
to change by The Company and its subsidiaries at any time without
notice.

EXTRA COPIES OF THESE INSTRUCTIONS ARE AVAILABLE FOR
INCLUSION IN EQUIPMENT / MAINTENANCE MANUALS THAT UTILIZE
THESE PRODUCTS. CONTACT YOUR LOCAL REPRESENTATIVE.

Installation and Service Instructions:
83-957-000

1/4" & 3/8"
H12 Pilot Controlled Regulator

ISSUED: September, 2002
Supersedes: November, 2001

ECN020442, Rev.2

Englewood, CO 80110

!

4. For protection against rust, pipe scale and other foreign

matter, install a filter on the upstream (high pressure) side
as close to the regulator as possible.