Specifications – USL PSA-200U User Manual
Page 17
![background image](/manuals/715163/17/background.png)
Page 17
1st Edition. October, 2004
USL, Inc.
PSA-200U Instruction Manual
• Equipment information, which
includes: manufacturer of lamp
housing and bulb, wattage, hours,
model of lamp house and serial
number.
(Fig. 15) Settings & Export
(Fig. 16) Export Settings
Specifications
1. Laptop Operating System Require-
ments: Windows 98SE (second edi-
tion), Windows ME (millenium edi-
tion), Windows 2000 or Windows XP.
2. Case Size: 21” x 13.5” x 7” (53cm x 34cm
x 18cm)
3. Weight: 19.5 lb (8.8 kg)
4. Power Requirements: 100 to 240VAC,
50 to 60 Hz at .07A (8.5W)
5. Luminance Measurement Range: three
to 30 foot-Lamberts (10-100cd/m)
Optionally 30 to 300 foot-Lamberts
(100-1000cd/m)
6. Luminance Measurement Accuracy:
±5%, ±2 digits
7. Spot Meter Acceptance Angle: ap-
proximately 1° when camera is 1.5
screen-widths distant from the movie
screen, and the screen image fills ap-
proximately 90% of the camera’s hori-
zontal image area.
8. Spot Meter Accuracy: ±5%, ±2 digits
9. Weave, Jitter and Flicker Measure-
ments Accuracy: ±10% of reading
10. Weave, Jitter and Flicker Measure-
ments Resolution: .05%
11. Environment: Temperature 40°-110° F,
Humidity 10% to 90% non-condensing