beautypg.com

Specifications – USL PSA-200U User Manual

Page 17

background image

Page 17

1st Edition. October, 2004

USL, Inc.

PSA-200U Instruction Manual

• Equipment information, which

includes: manufacturer of lamp

housing and bulb, wattage, hours,

model of lamp house and serial

number.

(Fig. 15) Settings & Export

(Fig. 16) Export Settings

Specifications

1. Laptop Operating System Require-

ments: Windows 98SE (second edi-

tion), Windows ME (millenium edi-

tion), Windows 2000 or Windows XP.

2. Case Size: 21” x 13.5” x 7” (53cm x 34cm

x 18cm)

3. Weight: 19.5 lb (8.8 kg)
4. Power Requirements: 100 to 240VAC,

50 to 60 Hz at .07A (8.5W)

5. Luminance Measurement Range: three

to 30 foot-Lamberts (10-100cd/m)

Optionally 30 to 300 foot-Lamberts

(100-1000cd/m)

6. Luminance Measurement Accuracy:

±5%, ±2 digits

7. Spot Meter Acceptance Angle: ap-

proximately 1° when camera is 1.5

screen-widths distant from the movie

screen, and the screen image fills ap-

proximately 90% of the camera’s hori-

zontal image area.

8. Spot Meter Accuracy: ±5%, ±2 digits
9. Weave, Jitter and Flicker Measure-

ments Accuracy: ±10% of reading

10. Weave, Jitter and Flicker Measure-

ments Resolution: .05%

11. Environment: Temperature 40°-110° F,

Humidity 10% to 90% non-condensing