Operating Guide | TS-700 Series

17

PARAMETER

FUNCTION

OPTIONS

C26
CAUTION:

Changing
these
parameters will
affect the
indicator’s
performance.

Standstill time

0 = quick
1 = medium
2 = slow

C27

Standstill range

1 = 1d 2 = 2d
5 = 5d 10 = 10d

(d = division)

C28
CAUTION:

Changing
these
parameters will
affect the
indicator’s
performance.

Digital filter
To compensate

for unstable
loads on the
weighing
platform (for
example, animal
weighing).

0 = close dynamic filter
1 = 1 digital filter strength
2 = 2 digital filter strength
3 = 3 digital filter strength
4 = 4 digital filter strength
5 = 5 digital filter strength
6 = 6 digital filter strength

C29
CAUTION:

Changing
these
parameters will
affect the
indicator’s
performance.

Noise filter

0 = disable noise filter
1 = 1 digital filter strength
2 = 2 digital filter strength
3 = 3 digital filter strength

C30

Format of date

print out

0 = yy.mm.dd
1 = mm.dd.yyyy
2 = dd.mm.yyyy
3 = yyyy.mm.dd

C31

Analog output

setting

0 = 0~5Vouput
1 = 4~20mA output

C32

RESERVED

-------