Parameters chart, Operating guide | ts-700 series – Triner Scale TS-700 Series V2.0 User Manual
Page 16

Operating Guide | TS-700 Series
14
PARAMETERS CHART
(For calibration parameters, see Appendix for Scale
Technicians, page A-4)
PARAMETER
FUNCTION
OPTIONS
C08
Warning tone
0 = Disable warning tone
1 = warning tone on
C09
Automatic
Power-off
0 = Disable auto off
10 = Power off in 10
minutes.
30 = Power off in 30
minutes.
60 = Power off in 60
minutes.
C10
Power saving
setting
(display
backlight on/off)
0 = Disable power saving
setting
3 = Display off in 3 min.
5 = Display off in 5 min.
C11
Hold function
0 = Disable hold function
1 = Hold peak weight
2 = Hold weight on scale
3 = Hold animal weight
4 = Reserved
Note: “hold peak weight”
will display the max. load
of multiple weighings.
C12
Kg/lb
conversion
0 = kg/lb conversion
disabled
1 = kg/lb conversion
enabled
C13
Upper/lower
limit alarm
C14
Lower limit
alarm value
Enter numeric values for
upper and lower
checkweighing limits.