beautypg.com

Appendix a – Triner Scale 600-E Series User Manual

Page 33

background image

Page A-1

APPENDIX A: SPECIFICATIONS

ANALOG SPECIFICATIONS

Full Scale Input Signal

30mV, including dead load

Minimum Sensitivity - Non H-44

0.4

µV / grad

Minimum Sensitivity - H-44

1.0

µV / grad

Input Impedance

30M

Ω, typical

Internal Resolution

Approximately 260,000 counts

Display Resolution

50,000 display division max

Measurement Rate

10 Meas/sec, nominal

System Linearity

Within 0.02% of FS

Calibration Method

Software Calibration, with long term storage in EEPROM

Excitation Voltage

+10VDC, 4 x 350

Ω load cells

DIGITAL SPECIFICATIONS

Microcomputer Intel

80C32

Program

Memory:

32K x 8, external to

µC

EEPROM:

64 x 16, external to

µC

Digital Filtering

Software selectable

SERIAL COMMUNICATIONS

Serial Port

Full Duplex, 1200, 2400, 4800, 9600 Baud
8 data bits, no parity, 1 stop bit
7 data bits, odd parity, 1 stop bit
7 data bits, even parity, 1 stop bit
7 data bits, no parity, 2 stop bits

OPERATOR INTERFACE

Display

0.56" (14 mm) 7-segment, Led, 6 Digit

Additional Symbols

Stable, Tare, lb, kg, Zero, Accu

Keyboard

4-key flat membrane panel

POWER

AC Adapter

12 VDC @ 800mA

DC Power Consumption - TI-500E

300mA + 30mA/350

Ω Load Cell

ENVIRONMENTAL

Operating Temperature

–10° to +40

° C

Storage Temperature

-25° to +70

° C