beautypg.com

Triner Scale 600-E Series User Manual

Page 13

background image

Page 2-5

3. Before beginning installation into the counter it is recommended to perform an initial

check of the scale system. Set the scale base on the floor, level the scale and plug all
components into the control module. All the ports on the control module and cables are
clearly marked (see fig. 2-3 for System Block Diagram). Place stainless steel platter
back onto the scale. Turn the scale on with the on/off switch located on the remote
keypad.

4. Remove the stainless steel top and disconnect all cables from the control module.

5. Mount the digital displays and keypad (see section 2.5).

6. Place the control module in the area beneath the scale and connect the display cables,

keypad cable and power cable.

7. The scale base must be grounded with the lead attached to the top frame. The center

screw on an electrical outlet or a metal conduit is usually suitable. Leave some slack in
the wire. Do not pull the wire tight because it can negatively affect weighing
performance.

8. Place the scale base in the location provided (bag well) and connect the load cell cable.

Leave some slack in the wire. Do not pull the wire tight because it can negatively affect
weighing performance.

9. Center the frame in the opening. Adjust the leveling legs so that the scale base is in a

level position. Make sure there is equal pressure on all four leveling feet. Thread the ¼-
20 jam nuts back onto the leveling leg rod and tighten against the load cell.

10. Use the Scale Anchor Holes on each leveling foot (see fig. 2-6) to secure the scale

base in place with the wood screws provided.

11. Place stainless steel cover back on the scale and test for accuracy.