Page 4-2

NAME/CODE DESCRIPTION CODE/VALUE

F9
Display
Divisions

Determines the desired weight increments. Value should be consis-
tent with legal requirements.

1
2
5

F10
Decimal Pt.

Determines location of the decimal point.

0 0.0

0.00 0.000
0.0000 00

F16
Zero Calibra-
tion

Places indicator into the zero calibration routine. Scrolling down with
the ZERO key one level begins the procedure.

Press ZERO key
to begin sequence

F17
Span Calibra-
tion

Places indicator into the span calibration routine. Scrolling down with
the ZERO key one level begins the procedure.

Press ZERO key
to begin sequence

F18
View Calibra-
tion

Actuates the function that allows you to view both the zero and span
calibration value. The values displayed in this function are valid only
after Calibration (F16 & F17) has been successfully completed.
Scrolling down with the ZERO key one level begins the procedure.

Press ZERO key
to begin sequence

F19
Key-in Zero

Allows you to key-in known zero calibration value in case of memory
loss in the field. Scrolling down with the ZERO key one level begins
the procedure.

Press ZERO key
to begin sequence

F20
Key-in Span

Allows you to key-in a known span calibration value in case of mem-
ory loss in the field. Scrolling down with the ZERO key one level be-
gins the procedure.

Press ZERO key
to begin sequence

F21
Factory Reset

This sub-menu will reset all parameters in the “F” and “A” menu to the
default settings. USE WITH CAUTION!

Press the ZERO
key twice to exe-