Page 7-2

7.2.1 FUNCTION

KEYS

lb/kg – This key toggles the indicator between lb and kg units if enabled in the User (“A”)
Menu. See Chapter 5 for more information.

Zero - This key sets the indicator to display zero and resets the bag accumulator provided
the following conditions are met:

1. The displayed weight is within the zero reset range that is programmed in F4 of the Setup

(“F”) Menu.

2. The scale is not in motion.
3. The scale is not in overload (see Appendix D for error codes).

Print - This key is used to send weight information out to the serial port provided the following
conditions are met:
1. The scale is not in motion.
2. The scale is not in overload (see Appendix D for error codes).

ACCU – This key is used to accumulate the weight of multiple bags and display the total.


7.3 GENERAL SCALE OPERATION

7.3.1 WEIGHING AN ITEM

1. Select the desired weighing unit by pressing the lb/kg key until that unit is indicated on

the display.

2. If necessary, press the ZERO key to obtain a weight reading of zero.

3. Place the object to be weighed on the scale’s platter and allow the weight indication to

stabilize. If the item weight exceeds the scale’s weight capacity, it displays “❐❐❐❐❐❐”.

4. Read the weight shown on the display.


7.3.2 ACCUMULATION

FUNCTION


1. Make sure scale is on zero. Press zero key if needed

2. Place

1

st

bag on the scale. The displays show the weight of the bag.

3. Press the ACCU button.

4. Remove

1

st

bag. Scale returns to Zero.

5. Place

2

nd

bag on scale. The weight of the 2

nd

bag will be displayed.

6. Press the ACCU button and the accumulated weight of both bags is displayed. (the

ACCU LED should also light up when accumulated weight is being displayed.) Follow
steps 4,5, and 6 for any additional bags.

7. When the last bag is weighed and the accumulated weight is recorded, empty the scale

and press the “zero” key to clear accumulations.