beautypg.com

Camera settings – Toa C-CC574 PL User Manual

Page 30

background image

30

NO

COM

NC

NO

COM

NC

[ Normal ]

[ Alarm ]

Rated, Maximum permissible voltage: 20 V DC
Permissible current limit: 1 A
Contact useful life: 100,000 times

13.3. About Alarm Input

No-voltage make contact input
Rated: open voltage: 18 V DC, short-circuit current: under 2 mA

NO – COM

NC – COM

Normal

Alarm

Open

Short

Open

Short

13. CAMERA SETTINGS

13.1. About AUX Output 1

Open collector output
Rated: withstand voltage: 20 V DC, permissible current: under 100 mA

13.2. About AUX Output 2 (C-CC564, C-CC574 only)

12.2. Camera Control Connector Connection (RS-485)

• Connect terminals (+) and (–) of the C-RM500 Remote Controller or the C-IF500 Interface Unit to the

camera's terminals (+) (terminal No. 8) and (–) (terminal No. 7), respectively.

• Connect the camera's terminals (+) and (–) to the next camera's terminals (+) and (–) in order.

Notes
• The maximum number of units connectable to a pair of RS-485 lines (from termination to termination) is 32

units including the Remote Controller. The maximum cable length connecting each terminal is 1.2 km in
total.

• The camera may not operate correctly if 32 or more units are connected or the total cable distance exceeds

1.2 km. In such cases, split or extend wiring using the C-IF500 Interface Unit.

• Indoor-use and outdoor-use combination cameras can be wired in free combinations.

Connect to the next
camera's terminal

Shield twisted pair cable

Connect to remote controller's
camera control terminal

Camera control
cable

Camera control
cable

GND

GND

This manual is related to the following products: