8.2. Mounting Procedures

1. Make a mounting hole of ø140 mm in the ceiling panel.

2. Install the anchor bolt for ceiling mounting bracket and anchor bolt for safety wire into the upper ceiling.

Notes
• The anchor bolt for ceiling mounting bracket must be aligned with the center of the mounting hole of ø140

mm in the ceiling panel, and must not project from the ceiling surface.

• If an existing anchor bolt is available nearby, it can be substituted for the anchor bolt for safety wire.

Anchor bolt for safety wire

Ceiling surface

Anchor bolt for ceiling mounting bracket

Upper ceiling

Ceiling panel

ø140 mm

3. Attach the supplied safety wire to the anchor bolt for safety wire.

4. Attach the ceiling mounting bracket to the end of the safety wire.

5. Attach the ceiling mounting bracket to the anchor bolt for ceiling mounting bracket.

Safety wire

Anchor bolt for ceiling
mounting bracket

C-BC511A
Ceiling Mounting Bracket
(optional)

*

Ensure close contact here.

5

Upper ceiling

Safety wire
(supplied with the C-BC511A)

C-BC511A
Ceiling Mounting Bracket
(optional)

Cam

era direc

tion

4

3