Toa C-CC574 PL User Manual
Page 22
22
4. Detach footings and saddle bracket on the camera mounting side from the suspension pipe.
• Removed saddle brackets and screws are attached to the suspension pipe in step 10.
• Removed footings and screws are attached to the base unit in step 12.
Saddle bracket and footing
on the camera mounting side
Suspension pipe
10.2. Mounting Procedures
1. Determine the suspending position, then make a mounting hole of ø50 – 60 mm in the ceiling plate.
2. Install the anchor bolt for safety wire into the upper ceiling.
• If an existing anchor bolt is available nearby, it can be substituted for the anchor bolt for safety wire.
3. Separately prepare a suspension plate, and cut out the necessary hole in a way best suited to the plate
material.
Anchor bolt for
safety wire
Ceiling panel
1
2
ø50 mm – 60 mm
• For strong ceiling materials
• For double-constructed ceilings
Camera direction
Suspension plate
Ceiling plate
Paper pattern
C-shaped channel
Suspension plate
Ceiling panel