beautypg.com

Connections, Connection example – Toa EV-20R User Manual

Page 11

background image

11

9. CONNECTIONS

9.1. Connection Example

*

1

Following activation, maintains make status until the message stops. When repeat broadcast mode is
selected by the Playback Interval Setting switch, the busy output during the time intervals (except for "0 s"
and "

" settings) can be set to "Make" (ON) or "Break" (OFF). (Refer to p. 13.)

Use these outputs for amplifier power supply control.

*

2

Messages are played back when their corresponding terminal numbers are closed.

*

3

Message playback stops when these terminals are closed.

*

4

Used for BGM broadcasts, etc. Whenever a stored message is activated, the message playback broadcast
takes precedence.

DEL

REC

MONITOR

PLAY

LOCK

0

10

1

2

3

4

USB

POWER

MIC

LEVEL

LINE

INPUT/
REC IN

HEAD-

PHONES

START/STOP

MODE

PHONES/

SPEAKER

4s

2s

ON

1h 30m

10m

1m

30s

DELAY

INTERVAL

TIMER

DC IN

GND

SIGNAL

0s

5m

5s

10s

OUT

24V

STOP

4

3

2

1

PLAY 1 – 4 / STOP

LINE IN

LINE OUT

DC IN

H

C

E

E

C

H

BUSY

SPKR

Class 2 Wiring / 8 – 16 Ω

24V 400mA

PC

To AC mains, 50/60 Hz
(When operating unit on AC power supply)

USB cable
(supplied with unit)

[EV-20R Front]

[EV-20R Rear]

Microphone

or

CD player, etc.

Headphone*

AD-246 AC adapter
(optional)

(When operating unit on DC power supply)

Timer or switching device

Speaker

External audio source equipment

Power amplifier

* No signal is output from the

Speaker Output terminal if
the headphone is connected.

Remote control input of power amplifier, etc.

24 V DC

power supply

STOP input*

3

LINE output

PLAY input*

2

LINE input*

4

BUSY output*

1

Remote control input

Stop control output

Start control output