2 display selector functions-set-up mode, 5 boom section "on/off" indicators -5, Speed – TeeJet TASC-6500 User Manual
Page 8: Area, L & chemicals - vol. appl, L & chemicals - appl. rate, L & chemicals - % rate, Carrier appl. rate, Carrier - vol. applied, Width
1-4
98-05019
Rev- 1
CE & S
TANDARD
V
ERSION
TASC 6200/6500
1.4.2 DISPLAY SELECTOR FUNCTIONS-SET-UP MODE
TASC-6500
CHEMICAL APPLICATORS
ON
OFF
Alt.-
Rate
1
2 3
4
5
6
7
8
9
BOOMS
MID-TECH
MIDWEST TECHNOLOGIES, INC.
%Rate
DISPLAY SELECTOR
Speed
Area
Width
Distance
Vol. Applied
Test
Speed
Fan RPM
Vol. Applied
Appl. Rate
Appl. Rate
Scan
RATE CONTROL CHANNELS
L & CHEMICALS
CARRIER
.
-Ac
Flow
RATE
Gal./
®
1
2
3
L
C
ON
OFF
Alt.-
Rate
1
2 3
4
5
6
7
8
9
BOOMS
MID-TECH
MIDWEST TECHNOLOGIES, INC.
%Rate
DISPLAY SELECTOR
Speed
Area
Width
Distance
Vol. Applied
Test
Speed
Fan RPM
Vol. Applied
Appl. Rate
Appl. Rate
Scan
RATE CONTROL CHANNELS
L & CHEMICALS
CARRIER
.
-Ac
./
L
C
SET- UP
OPERATE
%Rate
DISPLAY SELECTOR
Speed
Area
Width
Distance
Vol. Applied
Test
Speed
Fan RPM
Vol. Applied
Appl. Rate
Appl. Rate
Scan
RATE CONTROL CHANNELS
L & CHEMICALS
CARRIER
OFF
ON
DEC.
INC.
SET- UP
OPERATE
SPEED:
Ground Speed Override (GSO) Value. INC/DEC Switch changes.**
AREA:
Total accumulated Area.
L & CHEMICALS - Vol. Appl.:
Channel 1, 2, 3, or L Product switch "ON": Product Density. Channel 1, 2, 3,
or L Product switch "ALT-RATE": Cal. # for active channel. (Other channels, including C, must be off.) (Channel in
split drive: All booms with a programmed width must be on to view calibration number. Err is displayed until a
channel is selected.) Channel in non-peristaltic: Density. **
L & CHEMICALS - Appl. Rate:
The target application rates for channels 1, 2, 3, & L. Each channel can be
set to different rates in the "ON" and "ALT-RATE" positions.**
L & CHEMICALS - % RATE:
The percent of change in programmed application rate at which all five
channels are changed by each activation of the INC/DEC switch.**
CARRIER APPL. RATE:
The target application rate for the C Channel. Different rates can be programmed
into the "ON" and "ALT-RATE" positions. Displays Err unless C Channel switch is on.**
CARRIER - VOL. APPLIED:
C Channel Product switch - "ON": Product Density. C Channel Product switch
- Alt. Rate: Calibration number.**
WIDTH:
Individual boom section widths in inches (meters). Display cycles through all sections unless one section
is turned on. Each section width can be set, using the INC/DEC Switch, as the desired section appears on the display,
or the switch for each section can be turned "ON" individually. Boom Section C is the "Test Boom Width" used for
pump calibration etc. (normally set to the total boom width).**
DISTANCE:
The Distance Calibration Number.**
Fan RPM:
The current Fan RPM Calibration number. Should be set to the number of pulses the fan sensor will
generate for each revolution of the fan. This Cal. # can be set to zero to remove the FAN RPM reading from the
"SCAN" feature.**
TEST SPEED:
The current Test Speed.**
SCAN:
The "All Booms OFF" Hold/Close response is set in this position.
NOTES:
* Totals can be zeroed in this mode.
** Values are programmable in this mode.
***Values changeable by a % increase or decrease.