13 calibrating products 1,2 and 3 (tasc 6500 only), 1 calibrating mid-tech® injection pumps, 1 calibrating mid-tech® injection pumps -10 – TeeJet TASC-6500 User Manual
Page 20
2-10
98-05019
Rev- 1
CE & S
TANDARD
V
ERSION
TASC 6200/6500
2.13 CALIBRATING PRODUCTS 1,2 AND 3 (TASC 6500 ONLY)
Channels 1,2 or 3 can be used as either liquid injection channels or granular co-applicator channels. The calibration
methods are similar. It is necessary for you to be able to catch and measure the discharge from each channel.
NOTE: If you are using channels 1, 2, or 3, in "Flow Mode" follow the procedure in section 2.12 to calibrate except
the desired channel switch (1, 2, 3) must be turned on instead of the L channel switch.
2.13.1 CALIBRATING MID-TECH
®
INJECTION PUMPS
If you are using a MID-TECH
®
injection pump, use the following calibration numbers to get started. (Be sure the
channel is set to peristaltic drive, section 2.2 of the manual.)
The following values are typical calibration numbers (PC#’s) you can expect to see on MID-TECH
injection pumps after performing the field calibration procedure. If your pump calibration number
differs from the typical range, check the calibration. Enter these numbers for your initial pump calibra-
tion numbers, before conducting the actual prime or pump calibration procedure.
U.S. VALUES
MODEL #
DESCRIPTION
TYPICAL PC#
PC#
RANGE
TASC-20 PUMP
0.2 to 20-Oz./Min. (1/4"Dia. Tube)
32.0
27/37
TASC-50 PUMP
1.5 to 29-Oz./Min. (3/16"Dia. Tube)
65.0
58/72
TASC-50 PUMP
2.6 to 53-Oz./Min. (1/4"Dia. Tube)
110.0
100/120
TASC-100 PUMP
1.0 to 100-Oz./Min. (3/8"Dia. Tube)
145.0
130/160
TASC-150 PUMP
1.5 to 150-Oz./Min. (3/8"Dia. Tube)
145.0
130/160
TASC-200 PUMP
6.4 to 128-Oz./Min. (3/8"Dia. Tube)
285.0
256/314
TASC-200 PUMP
10.7 to 213-Oz./Min. (1/2"Dia. Tube)
485.0
436/534
TASC-350 PUMP
22.0 to 220-Oz./Min. (3/8"Dia. Tube)
285.0
256/314
TASC-350 PUMP
37.0 to 370-Oz./Min. (1/2"Dia. Tube)
485.0
436/534
METRIC VALUES
MODEL #
DESCRIPTION
TYPICAL PC# PC# RANGE
TASC-20 PUMP
5.9 - 591 Ml/Min. (2.75 mm Dia. Tube)
32.0
27/37
TASC-50 PUMP
44.0 - 858 Ml/Min. (2.75 mm Dia. Tube)
65.0
58/72
TASC-50 PUMP
76.9 - 1567 Ml/Min. (4.75 mm Dia. Tube)
110.0
100/120
TASC-100 PUMP
0.029 - 2.9 L/Min. (6.18 mm Dia. Tube)
145.0
130/160
TASC-150 PUMP
0.044 - 4.4 L/Min. (6.18 mm Dia. Tube)
145.0
130/160
TASC-200 PUMP
0.189 - 3.8 L/Min. (6.18 mm Dia. Tube)
285.0
256/314
TASC-200 PUMP
0.316 - 6.3 L/Min. (12.7 mm Dia. Tube)
485.0
436/534
TASC-350 PUMP
0.650 - 6.5 L/Min. (6.18 mm Dia. Tube)
285.0
256/314
TASC-350 PUMP
1.09 - 10.9 L/Min. (12.7 mm Dia. Tube)
485.0
436/534
IF IT IS NOT CONVENIENT TO CONDUCT AN ACTUAL CATCH TEST,
FIELD EXPERIENCE WILL ALLOW YOU TO FINE TUNE THE L CHAN-
NEL CALIBRATION NUMBER. IF CHANNEL L IS APPLYING TOO
MUCH, DECREASE THE CALIBRATION NUMBER BY THE SAME
PERCENTAGE AS THE OVER APPLICATION. IF CHANNEL L IS AP-
PLYING TOO LITTLE (YOU HAVE MATERIAL LEFT OVER) INCREASE
THE CALIBRATION NUMBER BY THE SAME PERCENTAGE AS THE
UNDER APPLICATION.