beautypg.com

Carrier WEATHERMAKER 48AJ User Manual

Page 12

background image

12

48AJ/AK L

O

W HEA

T

48AJ/AK HIGH HEA

T

48AJ/AK L

O

W HEA

T

48AJ/AK HIGH HEA

T

48A

W/A

Y

HIGH HEA

T

48A

W/A

Y

L

O

W HEA

T

48A

W/A

Y

L

O

W HEA

T

48A

W/A

Y

HIGH HEA

T

48AJ/AK051 L

O

W HEA

T

48AJ/AK051 HIGH HEA

T

48A

W/A

Y

051 L

O

W HEA

T

48A

W/A

Y

051 HIGH HEA

T

48AJ/AK060 L

O

W HEA

T

48A

W/A

Y

060 L

O

W HEA

T

48AJ/AK060 HIGH HEA

T

48A

W/A

Y

060 HIGH HEA

T

Fig. 10 — Cent

er

o

f Gra

v

ity

a

nd Wei

ght

s — 48

AJ

,AK,

AW,

A

Y0

51,

0

6

0

a50-8102

NO

TES:

1.

W

E

IGHTS

INCLUDE E

C

ONOMIZER OR O

U

TDOO

R AIR

DA

M

P

E

R

.

2.

CENTER OF

GRA

V

IT

Y

.

3

.

UNIT CL

EARANCES:

T

O

P

OF

U

N

IT

S

: N

O

O

V

ER

H

A

N

G

COND

E

N

SER COI

L

: 4

’ - 0“ [1

21

9]

ECONOMIZER S

ID

E

:

6’

-

0”

[

182

9]

HEA

T

S

IDE: 4

’’ - 0

” [12

1

9

]

FIL

T

E

R

A

CCESS

SIDE

: 15

’ - 0” [4

57

2] (FOR RE

MO

V

A

L

OF EV

APO

R

A

T

O

R COIL

)

4

.

FOR SM

AL

L

E

R SER

VICE A

ND OPERA

T

IO

N

A

L

CLEARANCES

,

CONT

A

C

T C

A

RR

IE

R

A

PPL

ICA

T

IO

N

ENGI

N

E

ERING DEP

A

R

T

-

ME

NT

.

5

.

BO

TT

O

M

DUCTS ARE

DESIGNED

T

O

BE A

T

T

A

CHED T

O

A

C

-

CESSOR

Y R

O

O

F

CURB

.

IF

U

N

IT I

S

MOUN

TED ON D

UNNA

GE,

IT I

S

RECOMMENDED THA

T

THE DUCTS BE SU

PPOR

TED BY

CR

OSS BRA

C

ES AS DONE O

N

A

CCESSOR

Y R

O

O

F

CU

RB

.

6

.

BASE

U

N

IT WEI

G

HTS INCL

UDE

OUTD

O

O

R AIR HOO

D

S AND

FIL

T

ERS (IND

O

O

R F

A

N M

O

T

O

R

IS

NO

T INC

L

UD

ED)

.

ADD

IN-

DOOR F

A

N MO

T

O

R, FIOPS

, AND A

CCESSORIES

FO

R

T

O

T

A

L

OP

ERA

T

ING WE

IGHT

.

7

.

V

A

V

MO

T

O

R W

E

IGHTS INCL

UDE INDOOR MO

T

O

R, VFD

, VFD

TRANSDUCER,

AND

ASSOCIA

TED

W

IRING

.

8.

DIMENSI

O

NS IN [ ] ARE

IN

MILL

IM

ETERS

. ALL

O

T

HER

DIMEN-

SI

ONS AR

E IN INCHES

.

9

.

FOR SIDE-SUPPL

Y/

RETU

RN APPLICA

T

IONS

, A

SINGL

E

RE-

TURN

AND SUPPL

Y D

UCTW

O

RK C

O

NN

ECT

ION

IS

RECO

M

-

MENDED

FOR C

O

VERING AL

L

THREE R

E

TUR

N

AND

ALL

THREE SUPP

LY

OPE

N

IN

G

S

. THE

ENTIRE

AREA

AR

OUND

THE DUCT OPENINGS I

S

A

V

AILABLE FOR A 1

.5”

D

UCT

F

L

ANG

E

A

T

T

A

CHM

EN

T

.

LEGE

ND

CV

Constant V

o

lume

FI

OP

F

a

ctor

y-Installed Option

IF

M

Indoor F

a

n Motor

VA

V

V

o

lume Ai

r v

o

lume

VFD

V

a

ri

a

b

le F

re

quency Dr

iv

e