Solvline Eddy Serial v2.5.1.1 User Manual
Page 77

Eddy User's Guide
77
AT+BTFP,n
Response
OK
Purpose
Set generation of link key every time of connection
Parameters n=0: Inactivate (Default)
n=1: Activate
Description If n is set to 1, Eddy-BT asks for the pin code every time a connection is made. This can
be used to increase security.
AT+BTSEC,Authentication,Encryption
Response
OK
Purpose
Set authentication and data encryption
Parameters
Authentication=0: Inactivate (Default)
Authentication=1: Activate
Encryption=0: Inactivate (Default)
Encryption=1: Activate
Description If the authentication is activated, the pin code must be set by AT+BTKEY command.
Data encryption cannot be used when authentication is not enabled, i.e.
Authentication=0 and Encryption=1 will not work properly.
AT+BTNAME=$
string
Response
OK
Purpose
Change device name
Parameters
$string= New device name (Default=”ESDV2_v2.0.0-445566”)
Description Eddy-BT can have a user friendly name for easy identification. The name allows up to 30
alpha-numeric characters.
Example
AT+BTNAME=”My-Eddy-BT”
AT+BTLPM,n
Response
OK
Purpose
Set low power mode
Parameters n=0: Inactivate (Default)
n=1: Activate
Description During no data transmission, Eddy-BT can be in low power mode to save the power. It
takes a few seconds to wake the Eddy-BT out of low power mode.