messages have either 11-bit or 29-bit headers. So a typical 11-bit exchange
would appear as follows:
Rx: 7DF 01 00
Tx: 7E8 41 00 BE 1B 30 13
Tx: 7E9 41 00 88 18 00 10
Tx: 7EA 41 00 00 08 00 10
Same exchange on 29-bit CAN:
Rx: 18DB33F1 01 00
Tx: 18DAF110 41 00 BE 1B 30 13
Tx: 18DAF118 41 00 88 18 00 10
Tx: 18DAF128 41 00 00 08 00 10
Monitoring can be turned off using the MON 0 command to increase the
refresh rate. To enable monitoring again, issue MON 1.
6.5 Status Messages
UART transmit buffer overflow detected.
User pressed the FAULT button.
The simulator is waiting for an ISO 9141-2 or ISO 14230-4 5 baud initialization
sequence.
The simulator is waiting for an ISO 14230-4 fast initialization sequence.
<5 BAUD INIT: OK>
Detected a successful 5 baud initialization sequence.
Detected a successful ISO 14230-4 fast initialization sequence.
All virtual ECUs had timed out, because a supported request had not been
received within P3
MAX
.