beautypg.com

Reznor Q6SP Option - Installation - Elec Heating User Manual

Page 12

background image

12

Figure 3. Wiring Diagram 9 kw, 1-Stage, 240 VAC

NOTES:

1.

If

any

of

the

original

wire

supplied

with

this

unit

must be replaced, it must be replaced with wiring material of the sam

e

gauge

size

and

temperture

rating.

2.

The

installation of

this

heater kit

may

require a

change in

the

blower speed.

See

Installation Instructions for

details.

3.

Use copper conductors with minimum temperature rating of 60C

for

supply

connections.

Legend

Field Wiring

Factory Wiring:

Low

Voltage

High Voltage

L1

L2

L3

UNIT

TERMINAL BLOCK

GND

PLUG

HOUSING,

6

PI

N

SEQUENCER

PLUG HOUSING,

3

PI

N

L1

T1

L2

L3

T2

T3

CONTACTOR

LIMI

T

LIMI

T

BK

W/WH

BK

W/WH

RD

W/BK

RD

W/BK

YE

W/BK

YE

W/BK

BK

W/WH

RD

W/BK

YE

W/BK

WHITE

BLACK

WHITE

BLACK

WHITE

WHITE

BLAC

K

WHITE

GRAY

RED

RED

1

2

3

4

5

6

M1

M2

M3

M4

1

2

1

2

12

3

12

3

CAP HOUSING, 3 PIN

710098A

This manual is related to the following products: