66
BEST BOY 4000
®
SPOT LUMINAIRE FIELD SERVICE MANUAL
Step
5. At Thermal Switch, disconnect two wires (Figure 3-38).
Step
6. Remove Thermal Switch Bracket and XYZ Assembly by removing four 8-32 x 1/2" SCBZ screws.
Figure 3-38: Removing XYZ Assembly
YEL
ORN
Thermal Switch Wires
XYZ Assembly
8-32 x 1/2" SCBZ Screw (4)
Thermal Switch Bracket
DETAIL A
Thermal
Switch
Reflector
- Apply Loctite 246