Testing, About this section, Test screen – PRG Best Boy Field Service Manual User Manual
Page 20

12
BEST BOY 4000
®
SPOT LUMINAIRE FIELD SERVICE MANUAL
TESTING
About This Section
The following section provides instructions for using the test and recalibration features of the Bad Boy menu system.
For complete menu operating instructions, refer to the Best Boy 4000 Spot Luminaire User Manual (02.9816.0001.xx).
Test Screen
The Test menu provides options for using the luminaire’s self-test features.
+
Recalibrate - press to bring up Recalibration Screen. (During
recalibration, intensity goes out until all mechanism calibrations are
complete and back in position, then fades in.)
+
Recal All - press to bring up Recalibrate All Yes/No options.
+
Disable - press to bring up Disable Screen, which allows specific
mechanisms to be disabled during testing.
+
Moiré Positions - press to bring up Moiré Gobos screen, which
provides a way to specify the wheel positions containing Moiré
gobos. Moiré gobos contain two pieces of glass: one that is fixed
and another that rotates. Due to this construction they do not
contain sensors, and therefore cannot be calibrated to a certain orientation at startup as with standard gobos.
+
Mech Test - press to bring up Mechanical Tests Screen. (See
on page 14 for more
explanation.)
+
Group Test - press to bring up Group Tests screen, which allows multiple luminaires to be run through a
configurable test sequence when chained together via DMX512 or Ethernet. (See
more explanation.)
+
Clean Lenses - press to bring up Cleaning Lenses screen. This feature will position lenses so that all surfaces
may be cleaned with a cloth. (Note that pressing the buttons does not actually clean the lenses.)
+
Fuse Map - press to bring up Fuse Map screen. The Fuse Map provides the circuit board location for all
mechanism fuses.
Test Screen