Connecting clock signal line – Mytek Digital Protools HDX DIO Card (ver. 2.0 / Nov 2013) User Manual
Page 12
Mytek Protools-HDX DIO Card – User's Manual
Connecting Clock Signal Line
Connecting Clock Signal Line
Connecting Clock Signal Line
Connecting Clock Signal Line
Single converter
If a single converter is used in the system, choosing internal
clock is the best solution. If external clock is used for
synchronization, SAMPLE RATE must be set to EXT. To do this,
press and hold EXT CLOCK SOURCE switch.
Regardless of synchronization source, choose in Pro Tools
software: Setup > Hardware Setup and select Internal on the Clock
Source tab.
Master 8x192 ADDA converter’s front panel
Clock source is typically internal, choose external only if you must use it
for systemic reasons.
Check if the selected sampling frequency of the converter (FS)
matches the sampling frequency in Pro Tools. If FS is double or
quadruple of external clocks frequency, WCK option must be set
to FS/4. FS/4 is the default setting and must be used whenever
multiple Digidesign I/O units are used in addition to master
8X192ADDA.
User's Manual ver. 2.0 / Nov 2013 www.mytekdigital.com
Page: 12 / 32