MFR_SERIAL
Reference:
Standard Command
Lockable:
Yes
Command Code:
0x9E
Format:
ASCII string
Data Bytes:
13
Units:
N/A
Transfer:
Read/Write Block
Factory Value:
String of 13 spaces (ASCII 0x20)
Description/Notes: See Section 22.2.6 of the PMBus Specification Part II.
Note that the MAX15303 implements MFR_SERIAL as a fixed-width string, not as part of a shared
memory space.
IC_DEVICE_ID
Reference:
Standard Command
Lockable:
N/A
Command Code:
0xAD
Format:
ASCII string
Data Bytes:
12
Units:
N/A
Transfer:
Read Block
Factory Value:
MAX15303AA00
Description/Notes: See Section 22.2.7 of the PMBus Specification Part II.
Note that the MAX15303 implements IC_DEVICE_ID as a fixed-width string, not as part of a shared
memory space.
IC_DEVICE_REV
Reference:
Standard Command
Lockable:
N/A
Command Code:
0xAE
Format:
ASCII string
Data Bytes:
8
Units:
N/A
Transfer:
Read Block
Factory Value:
Firmware revision (see Description)
Description/Notes: See Section 22.2.8 of the PMBus Specification Part II.
Note that the MAX15303 implements IC_DEVICE_REV as a fixed-width string, not as part of a shared
memory space.
The default value is the firmware revision number stored as an ASCII string, typically a 4-digit number.
The Maxim PowerTool™ GUI uses this information to identify the supported command set for a
particular slave device.