beautypg.com

Device identification commands, Capability, Pmbus_revision – Maxim Integrated MAX15303 PMBus Command Set User Manual

Page 35: Mfr_id

background image

MAX15303 PMBus Command Set User’s Guide

Page 35 of 52

Device Identification Commands

CAPABILITY

Reference:

Standard Command

Lockable:

N/A

Command Code:

0x19

Format:

Bit field

Data Bytes:

1

Units:

N/A

Transfer:

Read Byte

Factory Value:

0xA0

Description/Notes: See Section 11.12 of the PMBus Specification Part II.

PMBUS_REVISION

Reference:

Standard Command

Lockable:

N/A

Command Code:

0x98

Format:

Bit field

Data Bytes:

1

Units:

N/A

Transfer:

Read Byte

Factory Value:

0x22 (see Description)

Description/Notes: See Section 22.1 of the PMBus Specification Part II.

Note that due to a typographical error in the PMBus Specification version 1.2, wherein bit #4 is
omitted from the PMBUS_REVISION data byte, the Maxim interpretation is to correct this error and
include bit #4, placing the Part I Revision level in bits [7:4] and the Part II Revision level in bits [3:0].

e

Bits [7:4] describe the PMBus specification Part I revision level as follows:

0000 Revision 1.0
0001 Revision 1.1
0010 Revision 1.2

Bits [3:0] describe the PMBus specification Part II revision level as follows:

0000 Revision 1.0
0001 Revision 1.1
0010 Revision 1.2

MFR_ID

Reference:

Standard Command

Lockable:

Yes

Command Code:

0x99

Format:

ASCII string

Data Bytes:

8

Units:

N/A

Transfer:

Read/Write Block

Factory Value:

String of 6 spaces (ASCII 0x20)

Description/Notes: See Section 22.2.1 of the PMBus Specification Part II.

Note that the MAX15303 implements MFR_ID as a fixed-width string, not as part of a shared memory
space.

e

See the PMBus Specification, Part II, draft version 1.3, where this error is corrected to agree with the interpretation

described here.