beautypg.com

Status_input, Status_temperature, Status_cml – Maxim Integrated MAX15303 PMBus Command Set User Manual

Page 28

background image

MAX15303 PMBus Command Set User’s Guide

Page 28 of 52

STATUS_INPUT

Reference:

Standard Command

Lockable:

N/A

Command Code:

0x7C

Format:

Bit field

Data Bytes:

1

Units:

N/A

Transfer:

Read Byte

Factory Value:

N/A

Description/Notes: See Section 17.5 of the PMBus Specification Part II.

Bits #6, #5, #2, #1, and #0 are not implemented in the MAX15303 because the corresponding fault
commands are not supported.

STATUS_TEMPERATURE

Reference:

Standard Command

Lockable:

N/A

Command Code:

0x7D

Format:

Bit field

Data Bytes:

1

Units:

N/A

Transfer:

Read Byte

Factory Value:

N/A

Description/Notes: See Section 17.6 of the PMBus Specification Part II.

Bits #5 and #4 are not implemented in the MAX15303 because the corresponding fault commands
are not supported.

STATUS_CML

Reference:

Standard Command

Lockable:

N/A

Command Code:

0x7E

Format:

Bit field

Data Bytes:

1

Units:

N/A

Transfer:

Read Byte

Factory Value:

N/A

Description/Notes: See Section 17.7 of the PMBus Specification Part II.