MAX15303 PMBus Command Set User’s Guide

Page 13 of 52

VOUT_DROOP

accurate adaptive voltage positioning results with the VOUT_DROOP command.

Note that VOUT_DROOP can accept negative resistance values, allowing a user to compensation for
resistive losses between the output voltage remote sense point and the load, if desired. (Setting
VOUT_DROOP to a negative value will case output voltage to rise with increasing load.)

Wait at least 500μs for execution after sending the VOUT_DROOP command before sending
additional PMBus commands.