KERN & SOHN CFS 50K-3 User Manual
Page 49

3.
Call article
Press direct key e.g.
; the storage place number and the article name will
be shown for 1 second.
The display changes into the counting mode, the stored tare value e.g. 500 g
and the average piece weight e.g. 10g /pce. are displayed.
Place load on pan and read the number of pieces.
If connected to an optional printer, the data will be added up into the sum
storage and edited by pressing
.
Printout example CFS 50K-3 / KERN YKB 01N:
LOCAL SCALE
Active balance, see chap. 7.3
ID: 123456
User identification number (cf. chapter 12.2)
ABCDEF
Article name
1.9990 kg NET
Placed net weight
10 g U.W:
Average piece weight
200 pcs
Quantity placed on balance
TOTAL
--------------------------------
1.9990 kg NET
Total weight
200 pcs
Total number of pieces
1 NO
Number weighing processes
CFS/CCS-BA-e-1422
49